Specifications

SQ: 3-7
RS3: Service Quick Reference Guide
Power
Battery Charger Card 1984--1283--000x.............................
Battery Charger Card Test Points
Test Point
Function Comment
TP1 Return reference
TP2 Reference voltage 2.35 Volts Adjust with variable resistor R1
TP3 Battery voltage 27.6 Volts Adjust with variable resistor R2
Battery Charger Card Jumper Positions
Jumper
Purpose Position
HD1
Alarm contact for power
supply fault
1--2 N.O. -- Contact is normally open
2--3 N.C. -- Contact is normally closed
HD2
Alarm contact for battery
fault
1--2 N.O. -- Contact is normally open
2--3 N.C. -- Contact is normally closed
HD3 Battery connection
1--2 W BAT -- Test Battery every 24 hours
2--3 W/O BATT -- Do not test Battery
Battery Charger Card Fuses
Fuse
FRSI
Part No.
Bussman
Part No.
Littelfuse
Part No.
Characteristics
F1 G09140-0016 AGC 1/2 312.500
.5 A V 250 Quick
Acting
F2 G09140-0030 AGC 2 312002
2 A 250 V Quick
Acting