User guide
4 Introduction
1.6 Dispensing Valves
The D-580 Series Dispensing Systems support the following Nordson ASYMTEK jets, pumps, and valves.
Refer to the DispenseMate 580 Series Installation Guide for additional information.
Dispensing Valve Configuration
Valve Model
Valve Air
Connection
Fluid Pressure
Connection
Cooling Air
Connection
DJ-9000/DJ-2100 DispenseJet® Series Black fitting Clear fitting Green fitting
DV-7000/DV-8000 Heli-Flow® Pumps* N/A Clear fitting
DV-01 N/A Clear fitting
DV-07 Black fitting Clear fitting
DV-03HPA Black fitting Clear fitting
DV-05A Black fitting Clear fitting
DV-07 Black fitting Clear fitting
DV-09 Black fitting Clear fitting
* When using the DV-7000 or DV-8000 valve, make sure that the Valve Selector switch, DIP Switch 5 located on the
main board outside the electronics pan (Figure 1-2), is set to the proper position. The default setting is DV-8000 (up).
Switch 5 setting does not affect any of the other valves.
Figure 1-1 Valve Connections
Figure 1-2 Valve Selector Switch
Cooling Air Connection
(green)
Valve Air Connection
(black)
Fluid Pressure
Connection (clear)