28 Operation
3.8.2 Calibrating the Camera
To calibrate the camera:
1. Place a workpiece on the tooling plate and turn on the vacuum switch.
2. In the FmXP Main Window, click on Configuration > Setup Vision.
The Setup Vision Window opens.
3. Click on Calibrate.
The Calibration Window opens.
4. Position the camera over a fiducial and adjust the light level to obtain a good image
contrast.
If the image is not in focus, focus the camera as described below.
5. Click on Next.
6. Verify that the fiducial image is centered and click on Next.
The vision system will take a snap image of the fiducial.
7. If the fiducial is acceptable, select Next. If not, select Prev and define a new fiducial.
NOTE The fiducial should fit inside the green square on the camera image.
8. After the camera calibration sequence is complete, verify that the X and Y values are
relatively close to each other. If there is a large difference, repeat the calibration process
and define a new fiducial.
9. If the results are satisfactory, select Done to save the calibration results.
NOTE Machine offsets must be performed after calibrating the camera. For more information,
refer to the Fluidmove User Guide or Online Help.