User guide
Maintenance 43
4.6 Removing the Axis Covers
In order to perform the remainder of the maintenance procedures described in this section, it is necessary
to remove the axis covers (Figure 4-4).
To remove the axis covers:
1. Perform a system shutdown as described in 3.13 System Shutdown.
2. To remove the X-axis cover, loosen the two set screws and slide to the side.
DO NOT remove the spring pins.
3. To remove the Y-axis Cover, remove the two screws at the back and pull it forward.
Figure 4-4 Removing the Axis Covers
4.7 Lubricating the Cables and Linear Guides
The X-, Y-, and Z-axes support the dispensing head and allow it to travel within the dispensing area. To
ensure smooth dispensing head movement the rails and linear guides must be lubricated approximately
every three months. The location of the Mechanical Drive Cables is shown in Figure 4-5.
4.7.1 Lubricating the X-, Y-, and Z-Axis Cables
To lubricate the cables:
1. Remove the X- and Y-axes covers as described above.
2. Move each axis to its home position (X-axis far left, Y-axis rear, Z-axis upward).
3. Using a new lint-free cloth, wipe all cables to remove old grease or contamination.
4. Move each axis to its opposite end of travel and continue to wipe the cables clean.
5. Apply a light film of cable grease to all cables.
6. Move each axis back and forth over its entire length of travel four times to distribute
the grease.
7. Wipe off any excess grease.
8. When finished, replace the axis covers and tighten the screws.
NOTE When replacing the X-axis cover, make sure to place it on the spring pins.
X-Axis Cover
Set Screws
Y-Axis Cover
Screws
Spring Pins
(
DO NOT REMOVE
)