User`s guide

2
© 2009 Directed Electronics. All rights reserved.
b. Plug the three wire cable (P2) into the black
3-pin Bitwriter port of the Directed system.
CAUTION: Be careful NOT to plug this P2 con-
nector into the white Door Lock port which also
accepts an identical 3-pin connector. Electrical
damage will occur if plugged into this port.
c. Plug connector P1 into the SmartStart mod-
ule.
d. When power is connected, the module be-
gins an initialization procedure that may
take several minutes. During this procedure,
progress is reported via the ashing Amber/
Green LED’s next to the P1 connector. When
both LED’s turn on solid, the initialization pro-
cedure is completed (See Status LED's for a
description of the various LED states).
4. Re-verify security/remote start system operation:
Perform all basic operations such as Lock, Unlock,
Panic and Remote Start, (Trunk release where ap-
plicable) using the supplied remote control. If the
system operates as expected proceed to the next
step (5). If the system does not operate as ex-
pected, rectify the problem rst.
5. Verify and Activate the VSM100:
The following information and steps need to be
performed for the Verication/Activation of the
VSM100 Viper SmartStart module.
a. Customer Information:
Customer's Full Name:
Customer's Email Address:
Record/place Module ID # here:
New Account: Existing Account:
If this is an existing account, are you:
adding a new system:
or replacing an existing one:
b. Log on to:
www.viper.com/SmartStart/activate.
c. Enter customer information and module ID #
d. Click onscreen prompt to activate your sys-
tem.
e. Select whether you are activating the rst
SmartStart system for the customer (New Ac-
count) or adding a SmartStart system for a
customer with an existing account (Add a
Vehicle).
f. Activate module.
g. Test the SmartStart system from the website
using the supplied function links.
h. Print the customer information which includes
their temporary password. The customer is
also automatically notied via email, which
contains their temporary password and a
link they can click through to finish setting up
their account.
Note: SmartStart response time can vary depend-
ing on cellular coverage and network congestion.
Status LED's
Amber LED states:
Off: No cellular/Wi-Fi communication.
Check connections such as module har-
ness P1 (including D1).
Flashing slowly: The module is seeking
cellular or Wi-Fi system communication.
If no cell or Wi-Fi coverage is available
the Amber LED will continue to ash slow-
ly, move the vehicle to a location with bet-
ter reception.
Flashing quickly: The module is negotiat-
ing with a cellular or Wi-Fi system.
On solid: Communication successfully es-
tablished.
Green LED states:
Off: Communication not established with
the remote start main unit.
Check connection at the Bitwriter port,
once connected properly the LED will turn
on.
Flashing: Active communication in prog-
ress between the SmartStart module and
Remote Start main unit.
On solid: Communication successfully es-
tablished with the remote start main unit.
Please return this guide and printout from step 5h to
the owner after successfully completing the installa-
tion as it contains details required for account setup.
Additional information can be
found at: www.directechs.com
Logo, Directed Electronics w-driven.eps
Logo, Directed with designed in USA.eps
Logo, Directed with Distributed By.eps
Directed Logo Usage