Specifications
9261-7974 Issue 06
ESFIRECODER - Emergency Services Firecoder
Page 51
www.multitone.com
If the MTA can "listen" for incoming connections, the port number to listen on must be set in
the "Listen Port" parameter. This defaults to the MTA number (1..n) + 6000.
The WAN table will provide a list of remote nodes and corresponding IP addresses and port
numbers. This operates in much the same way as a standard dial up modem.
The "Connected To" parameter will contain the GD-92 node address of the currently
connected remote node.
6.58.3 Redirected Comm Port Connections
A redirected comm. port is usually addressed to connect to a remote Lantronix server or a
Firecoder/Access-1200 LAN interface. These connections are redirected from standard COM
ports, so can normally be used for any MTA type, though would normally only be used with the
Private Wire MTA.
The emulated DTR line is used to make/break the connection. The emulated DCD line is
asserted when the connection is made. This means that only MTA types that monitor these
lines should be used with TCP LAN connections, which normally excludes Asynch MTA's.
Only numerical network addresses are permitted. This is to speed up connection times and
reduce dependencies on name servers.
6.59 Peripheral Output Word
The hex value for a peripheral output command is the SUM of the following hex values:
Station Sounders 8000 Station Doors 0400
Station Lights 4000 Standby Sounder 0200
Spare Output 2 2000 Appliance Indicator 1 0080
Spare Output 3 1000
Spare Output 4 0800 Appliance Indicator 8 0001
For example, to set the Sounders, Lights and Doors, the value should be set to 8000+4000+0400 =
C400.