Technical data

31
Central vacuum systems
Every dust separator is equipped with a by-pass
valve for the vacuum of air which acts when in the
piping there is too much suction power.
On the systems with 2,2 kW motors the by-pass
valve on the dust separator should be always
closed.
The by-pass valve is used only on the systems
with 5,5 kW motors, when on a motor just one
operator is working. The excess of vacuum power
is compensated by the by-pass valve Check that
the valve is open and adjust eventually the bolt
for a maximal efficiency.
Steps for the adjustment of the by-pass valve
1. with a wrench unscrew the bolt of the cover 1
and remove the metal cover and remove the
soundproof cover 2.
In the case that in the piping some by-pass valves
will be installed for the self-cleaning of the lines,
close the valve on the dust separator and adjust
such valves as described in the paragraph “Check
of the functioning of the by-pass valve on the dust
separator”.
Steps for the adjustment
1. After having removed the soundproof cover of
the valve, start the system by inserting 2 flexible
hoses into the inlet valves.
2. Adjust the valve as described in the paragraph:
“Check of the functioning of the by-pass valve on
the dust separator”.
Check of the functioning of the
by-pass valve on the dust separator
By-pass
valves adjustment
2. start the system by inserting the 2 flexible hoses
into the inlet valves and vacuum by both of them.
3.adjust with a wrench the by-pass valve 3, by
opening it until when an air infiltration could be
heard
4. remove one flexible hose from the inlet valve and
check that the inlet valve starts working again
5. close the valve to the closing
6. reassemble the soundproof cover
3
Z 864
1
2
Z 863