Discover Manual

10
discoverbattery.com
CAUTION!
Do not charge battery higher than 3.4 V per cell module.
NOTE!
Recommended charge current is 0.5C
Model
Cell Modules
in Series
Bulk Current
Absorption
Voltage
Termination
Charge Current
14-12-3000 4 S 150 Adc maximum 13.6 V
I2 ≤ 2 A
14-24-3000 8 S 114 Adc maximum 27.2 V
14-36-3000 12 S 76 Adc maximum 40.8 V
14-48-3000 16 S 57 Adc maximum 54.4 V
7.4 Discharging
Set the battery to ON
Set the load to ON
Recommended low voltage cut off: 12 V | 24 V | 36 V | 48 V
NOTE!
Do not discharge battery below the recommended
minimum operating voltages.
NOTE!
Do not discharge battery at rates greater than
recommended operating currents.
7.5 Storage
Systems should be turned off and stored out of direct sunlight in compliance with the following temperature conditions:
Recommended Minimum -10°C / 14°F
Recommended Maximum 30°C / 86°F
Batteries should never be stored at 100% SOC. Store batteries at approximately 80% SOC and checked monthly to ensure the
SOC does not fall below 20%. At 20% SOC the battery will self discharge in approximately 2 months.
CAUTION!
Do not store a discharged battery. Recharge battery after every
use. Batteries that have self-discharged to a severely discharge
state are not recoverable.
8. Service & Maintenance
8.1 Warranty Registration
To register your product you will need the serial number of the battery. Visit discoverbattery.com for registration details.
8.2 Inspection
Batteries should be carefully inspected on a regular basis in order to detect and correct potential problems before they do harm.
This routine should be started when the batteries are rst received.
Inspect for cracks in the battery casing
Check battery terminals and connections to make sure they are clean, free of dirt, uids and corrosion