▲ CAUTION!
Do not charge battery higher than 3.4 V per cell module.
▲ NOTE!
Recommended charge current is 0.5C
Model
Cell Modules
in Series
Bulk Current
Absorption
Voltage
Termination
Charge Current
14-12-3000 4 S 150 Adc maximum 13.6 V
I2 ≤ 2 A
14-24-3000 8 S 114 Adc maximum 27.2 V
14-36-3000 12 S 76 Adc maximum 40.8 V
14-48-3000 16 S 57 Adc maximum 54.4 V
7.4 Discharging
• Set the battery to ON
• Set the load to ON
• Recommended low voltage cut off: 12 V | 24 V | 36 V | 48 V
▲ NOTE!
Do not discharge battery below the recommended
minimum operating voltages.
▲ NOTE!
Do not discharge battery at rates greater than
recommended operating currents.
7.5 Storage
Systems should be turned off and stored out of direct sunlight in compliance with the following temperature conditions:
Recommended Minimum -10°C / 14°F
Recommended Maximum 30°C / 86°F
Batteries should never be stored at 100% SOC. Store batteries at approximately 80% SOC and checked monthly to ensure the
SOC does not fall below 20%. At 20% SOC the battery will self discharge in approximately 2 months.
▲ CAUTION!
Do not store a discharged battery. Recharge battery after every
use. Batteries that have self-discharged to a severely discharge
state are not recoverable.
8. Service & Maintenance
8.1 Warranty Registration
To register your product you will need the serial number of the battery. Visit discoverbattery.com for registration details.
8.2 Inspection
Batteries should be carefully inspected on a regular basis in order to detect and correct potential problems before they do harm.
This routine should be started when the batteries are rst received.
• Inspect for cracks in the battery casing
• Check battery terminals and connections to make sure they are clean, free of dirt, uids and corrosion