S7000 Series TV Analyzer Operation Manual Version 1.3 © TianJin Deviser Electronics Instrument Co., Ltd. All rights reserved. Printed in CHINA.
S7000 Series TV Analyzer Operation Manual Contents 1. The Basics .......................................................................................................................................................... 1 1.1 General Information .................................................................................................................................. 2 1.1.1 Helpful Website .............................................................................................................
S7000 Series TV Analyzer Operation Manual 3.4 Channel Scan ........................................................................................................................................... 67 3.4.1 Parameters....................................................................................................................................... 67 3.4.2 Operation.........................................................................................................................................
S7000 Series TV Analyzer Operation Manual 4.6.2 Operation....................................................................................................................................... 108 5. TS Monitor & Analysis.................................................................................................................................... 109 5.1 Brief introduction ...................................................................................................................................
S7000 Series TV Analyzer Operation Manual 5.13.1 Description .................................................................................................................................... 129 5.13.2 Operation....................................................................................................................................... 130 5.14 Parameter Setting ..................................................................................................................................
S7000 Series TV Analyzer Operation Manual 1.
S7000 Series TV Analyzer Operation Manual 1.1 General Information 1.1.1 Helpful Website http://www.devisertek.com 1.1.2 Warranty and Service Warranty The instrument is warranted for 12 months under normal operating conditions (except battery). Users should read manual carefully before first use and operate correctly according to the manual.
S7000 Series TV Analyzer Operation Manual and ATSC standard. Section 6: IPTV- introduces IPTV. Section 7: File Management- provides file management, including: picture and data view, delete, transfer, rename and so on. Section 8: Appendix- provides specification and annotation. 1.1.4 ESC(Electrostatic Discharge) Electrostatic discharge can damage or destroy electronic components, therefore, all work on electronic assemblies should be performed at an antistatic workstation.
S7000 Series TV Analyzer Operation Manual 1.2 Getting Started 1.2.1 Overview S7000 is a versatile TV analyzer which supports DVB-C/S/S2/T/T2 standard digital TV analysis, MPEG1/2/4, H.264 Video Record, TS analysis and spectrum analysis. 1.2.2 Shipping Inspection After removing the instrument from its packaging, perform the following steps: 1) Take the instrument out of the case to ensure that no damage occurred during shipment. Unload the case carefully and check the package.
S7000 Series TV Analyzer Operation Manual 1.3 Getting to know S7000 1.3.1 Front Panel 4 1 16 2 3 11 5 10 14 7 8 9 6 15 13 12 Figure 1-1 TFT LCD: 7”, Resolution: 800×480. 1.3.1.1 Indicator 1) External DC charger operation indicator. 2) Power ON/OFF indicator. 3) External instruments power supply indicator. 1.3.1.2 Keyboard 4) Power ON/OFF key, press this key and hold to turn the device on and off. 5) TV key, this key is used to enter into TS Monitor & Analysis function.
S7000 Series TV Analyzer Operation Manual 13) TAB key, this key is used to switch marker. 14) UP key, DOWN key, LEFT key, RIGHT key, the keys are used to move cursors and change the value within a function display. 15) Keypad, these keys are used to enter alphanumeric characters. 16) Function soft keys, these keys are used to access various functions within the display. 1.3.1.3 Title Bar Figure 1-2 a. TS-ASI indicator. It indicates that ASI function works when this icon appears on the title bar.
S7000 Series TV Analyzer Operation Manual 1.3.2 Left Panel Fan Figure 1-3 1.3.
S7000 Series TV Analyzer Operation Manual 1.3.4 Rear Panel RF input DVB-CI Horn Battery TS-ASI Output TS-ASI Input Figure 1-5 NOTE: RF input: DC~100Hz, 30VDC, 5MHz~2150MHz, +21dBm.
S7000 Series TV Analyzer Operation Manual 1.3.5 Power Supply S7000 is powered by both built-in battery and external power adapter. Please charge S7000 before using. 1.3.5.1 Battery S7000 TW use built-in 7.4V/13AH Li-Polymer battery and work over 5 hours when fully charged. Once the voltage of the battery is lower than 7.15V, S7000 TW pops up a message box: LOW BATTERY! Once the voltage of the battery is lower than 6.8V, S7000 TW pops up a message box: LOW BATTERY! and the battery icon flashes.
S7000 Series TV Analyzer Operation Manual 2.
S7000 Series TV Analyzer Operation Manual 2.1 Setup 2.1.1 Overview The instrument enables you to select from numerous instrument setup and utility functions. This chapter will provide you with instructions on how to utilize the functions available in the Setup Menus of the instrument. Perform the following steps to enter the Setup Window: 1) Select key (HOME) to return to the main Menu. 2) Select key (SETUP) then the Setup Window will appear with the ABOUT Tab displayed.
S7000 Series TV Analyzer Operation Manual 2.1.2 System Information Select the ABOUT Tab to display the system information (default selection when entering the Setup Window). The following information is included in the ABOUT Tab, as refer to the Figure 2-1. Figure 2-1 Press keys (UP/DOWN) to the second page as Figure 2-2.
S7000 Series TV Analyzer Operation Manual 2.1.3 General Settings Select the GENERAL Tab to display and adjust the general system settings. The following settings are included in the GENERAL Tab, as shown in Figure 2-3. Network Settings PING Display and Battery Settings Date and Time Settings Skin Settings Language Settings Operator Name Factory Reset 2.1.3.1 Network Settings Users may access network with RJ45 connection.
S7000 Series TV Analyzer Operation Manual Manual Network Settings, refer to Figure 2-4. To enable manual network parameters, perform the following steps: 1) While the DHCP check box is not selected, select key (TAB) or keys (UP/DOWN/LEFT/RIGHT) to highlight the first segment of the IP ADDR field. Refer to Figure 2-4. 2) Use the Alphanumeric Keypad to enter the address value.
S7000 Series TV Analyzer Operation Manual 2.1.3.2 PING PING is used to check the network smooth and the connection speed. The current IP address of S7000 is regarded as the source IP (If you want to amend IP address, you should select NETWORK.). Please connect S7000 and the destined instrument by LAN line, input the destined IP address in the column (Please make the two IP address on the same network segment), then press START to start testing. During testing, START will be STOP.
S7000 Series TV Analyzer Operation Manual 2.1.3.3 Display and Battery Settings From the GENERAL Tab, select keys (UP/DOWN) to enter the DISPLAY&BATTERY setup screen. The following information is included in the DISPLAY&BATTERY Tab, as shown in the Figure 2-6. Backlight Settings Select keys (LEFT/RIGHT) and key (ENTER) to adjust the backlight.
S7000 Series TV Analyzer Operation Manual 2.1.3.4 Date and Time Settings The Date and Time Settings allows the user to set the system date and time as shown in the Figure 2-8. Figure 2-8 Select 2.1.3.5 keys (UP/DOWN/LEFT/RIGHT) and key (ENTER) to adjust the local date and time. Skin Settings The Skin Settings allows the user to change the system skin as shown in the Figure 2-9.
S7000 Series TV Analyzer Operation Manual 2.1.3.6 Language Settings The Language Settings allows the user to set the system language as shown in the Figure 2-10. After the language is selected, S7000 will transform menus to the selected language automatically. Figure 2-10 NOTE: Contact us for more local languages. 2.1.3.7 Operator Name The operator name and company can be entered into S7000 as shown in the Figure 2-11.
S7000 Series TV Analyzer Operation Manual 2.1.4 Measurement Settings Select the MEASURE Tab to display and adjust the measurement settings. The following settings are included in the MEASURE Tab. HUM Settings Level Unit Settings TP COMPENSATION Display Format Digital TV mode ANALOG TV mode 2.1.4.1 HUM Settings S7000 supports HUM measurement to ANALOG channel. HUM modulation is also named as power HUM modulation distortion, which caused by low-frequency interference of the power.
S7000 Series TV Analyzer Operation Manual 2.1.4.2 Level Shift Settings S7000 allows the user to make adjustments to compensate for various measured data in the Level and Channel Scan functions by adjusting the Level Shift value as shown in the Figure 2-13. Select keys (UP/DOWN/LEFT/RIGHT), key (ENTER) and the Alphanumeric Keypad to enter a Level Shift value from -3dB to +3dB. Figure 2-13 Also, S7000 allows the user to select the desired measure level unit dBμV, dBmV, or dBm as the Figure 2-14.
S7000 Series TV Analyzer Operation Manual 2.1.4.3 TP COMPENSATION S7000 allows the user to make adjustments to compensate for test probe by adjusting the compensation value as shown in the Figure 2-15. Figure 2-15 Select keys (UP/DOWN/LEFT/RIGHT), key (ENTER) and the Alphanumeric Keypad to enter a compensation value from 0dB to +40dB. When TP COMPENSATION is not selected, users can not edit the compensation. Refer to Figure 2-16.
S7000 Series TV Analyzer Operation Manual 2.1.4.4 Display Format S7000 supports two different displayed formats: Decimalism and Hexadecimal, as shown in the Figure 2-17. This function will be used in TS Measurement. Figure 2-17 2.1.4.5 Digital TV Mode S7000 supports two different digital TV modes: ATSC and DVB, as shown in the Figure 2-18. This function will be used in TS Measurement.
S7000 Series TV Analyzer Operation Manual 2.1.4.6 ANALOG TV Mode The interface of ANALOG TV Mode is shown as Figure 2-19.
S7000 Series TV Analyzer Operation Manual 2.1.5 Channel Settings Select the CHANNEL Tab to display and adjust the channel settings. The following settings are included in the CHANNEL Tab. Selecting an Active User Channel Plan Learning a User Channel Plan Editing a User Channel Plan Editing a Tilt Measurement Channel Plan Satellite List Adding Satellite 2.1.5.1 Select User Channel Plan Up to sixteen user channel plans can be built and saved.
S7000 Series TV Analyzer Operation Manual 2.1.5.2 Learn User Channel Plan Before attempting to use S7000, the user must create a User Channel Plan. Once completed, this will allows S7000 to measure all the channels automatically and save the various measurement data. Perform the following steps to learn a User Channel Plan: Connect S7000 to the cable system. 1) Select keys (UP/DOWN) to select the LEARN USER PLAN, as shown in Figure 2-21.
S7000 Series TV Analyzer Operation Manual Figure 2-21 Figure 2-22 Figure 2-23 26
S7000 Series TV Analyzer Operation Manual 2.1.5.3 Edit User Channel Plan You can set the channel number plan type to be displayed in Digital (numeric) Mode (also known as EIA Mode) or Standard (alphanumeric) Mode as the Figures 2-24 and 2-25. Select keys (UP/DOWN) and key (ENTER) to edit each individual channel. Select SELECT, S7000 will display the interface of Channel information and the user can enable the channel (See Section 2.2). Select ENABLE ALL, all the channels are enabled.
S7000 Series TV Analyzer Operation Manual 2.1.5.4 Edit Tilt Plan Up to sixteen channels can be tested in Tilt Measurement Mode. Select keys (UP/DOWN) and key (ENTER) to enable the channels you wish to add to the Tilt Measurement. (To disable a marked channel, select key (ENTER) again.) The ‘√’ indicator is shown to mark the enabled channels. They will be displayed in sequence according to their frequency value in the table, as shown in the Figure 2-26.
S7000 Series TV Analyzer Operation Manual 2.1.5.5 Satellite List Before attempting to use the SATELLITE function in S7000, user must edit the desired satellite list. Once completed, this will allow S7000 to measure all the satellites automatically and save the various measurement data. Select keys (UP/DOWN) and key (ENTER) to enable the satellites you wish to add to the Satellite List. (To disable a marked satellite, select key (ENTER) again.
S7000 Series TV Analyzer Operation Manual 2.1.5.6 Adding Satellite S7000 allows the user to add the desired satellite to the list, as shown in the Figure 2-28. Select keys (UP/DOWN/LEFT/RIGHT), key (ENTER) and Alphanumeric Keypad to enter the satellite name, longitude, and the amount of transponder. After adding, the satellite will automatically be added to the list.
S7000 Series TV Analyzer Operation Manual 2.1.6 INTERFACE Select the INTF. Tab to display and adjust the external ports settings. The following settings are included in the INTF. Tab. LNB Power TS Interface GPS 2.1.6.1 LNB Power Select keys (UP/DOWN) and key (ENTER) to select the LNB Power. The LNB power supply screen for Cable & Terrestrial band is shown as the Figure 2-29. The LNB power is used for antenna.
S7000 Series TV Analyzer Operation Manual The instructions of LNB power is following. LNB power AUTO 13V 18V 13V+22K 18V+22K 24V 2.1.6.2 Instruction The instrument will run the LNB power automatically according to the current satellite setup.
S7000 Series TV Analyzer Operation Manual 2.1.6.3 GPS When the external GPS is not connected, S7000 allows the user to configure GPS manually to calculate installation angle of the dish, when the external GPS is not connected with S7000, as shown in the Figure 2-32. When the external GPS is connected, or icons will appear on the main title and S7000 will position automatically. : Searching for the positioning. : Positioning successfully, the detailed GPS information will appear as the Figure 2-33.
S7000 Series TV Analyzer Operation Manual 2.2 Channel Information Setup 2.2.1 Brief Introduction S7000 allows the user to view and/or adjust the measurement configuration according to the channel types, ANALOG TV, DVB-C, DVB-T, DVB-T2, DTMB, ANALOG FM and DVB-S/S2. Select key (CH INFO) to view the channel/satellite information at any measurement screen in cable & terrestrial system or satellite system. 2.2.2 Cable & Terrestrial System 2.2.2.
S7000 Series TV Analyzer Operation Manual 2.2.2.2 DVB-C In the channel type of DVB-C, the following settings are included as shown in the Figure 2-35. Also select keys (UP/DOWN) and Alphanumeric Keypad to adjust them. EIA NUMBER, Digital channel number. SID NAME, Standard channel number. STATUS, Channel status. SIGNAL TYPE, Channel type. FREQ, Frequency. MEASURE BW, Bandwidth. MODULATION, Modulation Type. STANDARD, Standard. SR, Symbol Rate.
S7000 Series TV Analyzer Operation Manual 2.2.2.3 DVB-T In the channel type of DVB-T, the following settings are included as shown in the Figure 2-36. Also select keys (UP/DOWN) and Alphanumeric Keypad to adjust them. EIA NUMBER, Digital channel number. SID NAME, Standard channel number. STATUS, Channel status. SIGNAL TYPE, Channel type. FREQ, Frequency. MEASURE BW, Bandwidth. MODULATION, Modulation Type. GUARD, Guard Interval. FFT MODE, Carriers mode. CODE RATE.
S7000 Series TV Analyzer Operation Manual 2.2.2.4 DVB-T2 In the channel type of DVB-T2, the following settings are included as shown in the Figure 2-37. Also select keys (UP/DOWN) and Alphanumeric Keypad to adjust them. EIA NUMBER, Digital channel number. SID NAME, Standard channel number. STATUS, Channel status. SIGNAL TYPE, Channel type. FREQ, Frequency. MEASURE BW, Bandwidth.
S7000 Series TV Analyzer Operation Manual 2.2.2.5 DTMB In the channel type of DTMB, the following settings are included as shown in the Figure 2-38. (UP/DOWN) and Alphanumeric Keypad to adjust them. EIA NUMBER, Digital channel number. SID NAME, Standard channel number. STATUS, Channel status. SIGNAL TYPE, Channel type. FREQ, Frequency. MEASURE BW, Bandwidth.
S7000 Series TV Analyzer Operation Manual 2.2.2.6 ANALOG FM In the channel type of ANALOG FM, the following settings are included as shown in the Figure 2-39. Select keys (UP/DOWN) and Alphanumeric Keypad to adjust them. EIA NUMBER, Digital channel number. SID NAME, Standard channel number. STATUS, Channel status. SIGNAL TYPE, Channel type. FREQ, Frequency. Figure 2-39 2.2.2.7 Operation RESET Select this soft key to restore the factory default setup.
S7000 Series TV Analyzer Operation Manual 2.2.3 Satellite System The satellite system information includes the following two parts: 1) The satellite and receiver (satellite name, longitude, LO OSC, HI OSC). 2) The transponder (transponder name, channel status, signal type, polarization, LNB OSC, Frequency (Ku, C), Bandwidth (Code Rate, modulation type, Roll Off, SR)). 2.2.3.1 DVB-S/S2 In the channel type of DVB-S, select keys (UP/DOWN) and Alphanumeric Keypad to adjust those parameters above.
S7000 Series TV Analyzer Operation Manual 2.2.3.2 ANALOG TV Figure 2-42 2.2.3.3 Operation SAT+ TP+ RESET Select this soft key to restore the factory default setup. SAVE Select this soft key to save the changes, then the remind dialog box will appear: Are you sure to save the changes? Select ‘YES’ to save and ‘NO’ to exist without saving. SATTP- Select these two soft keys to switch the enabled satellite list. Select these two soft keys to switch the current transponder.
S7000 Series TV Analyzer Operation Manual 3.
S7000 Series TV Analyzer Operation Manual The main menu of CAB&TERR is shown in Figure 3-1. Figure 3-1 The function icons of the main menu are defined as follows: ---- Channel measurement ---- Constellation diagram measurement ---- Spectrum analysis ---- Tilt measurement ---- Channel scanning measurement Press keys (LEFT/RIGHT) to select the relevant function icons, and you can press the relevant interfaces.
S7000 Series TV Analyzer Operation Manual Figure 3-2 Up to sixteen user plans can be built and saved. The user plans are named as UsrPlan00 - UsrPlan15. Users can define one plan as the current user channel plan and edit the name of the current user channel plan. Users can learn the user channel plan after selecting (See Section 2: SETUP->CHANNEL->LEARN USER PLAN). Users can edit the parameters according to need. Press key (CH INFO) to enter the interface of channel setup. Refer to Figure 3-3.
S7000 Series TV Analyzer Operation Manual 3.1 Channel Measurement The function of Channel Measurement is used to test the basic parameters of the relevant channel types, and the channel types are as follows: 1) ANALOG TV 2) DVB-C 3) DVB-T/T2 4) DTMB 5) ANALOG FM Channel Measurement supports for different setup parameters and measurement parameters according to different channel types, as follows: 3.1.1 ANALOG TV The interface of ANALOG TV Channel Measurement refers to Figure 3-4.
S7000 Series TV Analyzer Operation Manual 3.1.1.2 Operation CNR Press the key to enter CNR function directly. HUM Press the key to enter HUM function directly and the function is only enable for ANALOG TV. MOD Press the key to enter MOD function directly and the function is only enable for ANALOG TV. SPECT Press the key to enter SEPCTRUM function directly. 46 ENTER key, press the key to enter the entry status of parameters and makes the character keys work.
S7000 Series TV Analyzer Operation Manual 3.1.2 DVB-C The interface of DVB-C Channel Measurement refers to level/MER/PRE-BER/POST-BER and so on. Figure 3-5. It can measure Power Figure 3-5 3.1.2.1 Parameters CH, Show the channel number of the current channel. FREQ, frequency (5MHz ~1050MHz). BW, bandwidth (1MHz ~50MHz). MODE, modulation type. When STD is J.83A and J.83C, MODE is 16QAM, 32QAM, 64QAM, 128QAM and 256QAM; When STD is J.83B, MODE is 64QAM and 256QAM; When STD is J.
S7000 Series TV Analyzer Operation Manual 3.1.3 DVB-T The interface of DVB-T Channel Measurement refers to Figure 3-6. It can measure Power level/MER/CBER/VBER and so on. Figure 3-6 NOTE: The MER displayed on the Channel Measurement interface is the average MER of all carriers. 3.1.3.1 Parameters CH, channel. Show the number of the current channel. FREQ, frequency (5MHz ~1050MHz). BW, bandwidth (6MHz, 7MHz, 8 MHz). MODE, modulation type (QPSK, 16QAM, 64QAM).
S7000 Series TV Analyzer Operation Manual 3.1.4 DVB-T2 The interface of DVB-T2 Channel Measurement refers to Figure 3-7. It can measure Power level/MER/CBER/LBER and so on. Figure 3-7 3.1.4.1 Parameters CH, Show the channel number of the current channel. FREQ, frequency (5MHz ~1050MHz). BW, bandwidth (6MHz, 7MHz, 8MHz). PLP ID. The default PLP ID is 0. The instrument can get the PLP information automatically when the current channel is locked.
S7000 Series TV Analyzer Operation Manual 3.1.5 DTMB The interface of DTMB Channel Measurement refers to Figure 3-8. It can measure Level, MER, BER and so on. Figure 3-8 3.1.5.1 Parameters CH, Show the channel number of the current channel. FREQ, frequency (5MHz ~1050MHz). BW, bandwidth (6MHz, 7MHz, 8MHz). 3.1.5.2 Operation VIEW Press the key to switch the display between Power level/MER/CBER/LBER, when the current channel type is DVB-T2.
S7000 Series TV Analyzer Operation Manual 3.1.6 ANALOG FM The interface of ANALOG FM Channel Measurement refers to Figure 3-9. It can measure Level and so on. Figure 3-9 3.1.6.1 Parameters CH, Show the channel number of the current channel. FREQ, frequency (5MHz ~1050MHz). STEP (0.01MHz ~10MHz). 3.1.6.2 Operation LISTEN Press the key to listen to FM intuitively. Users can press keys (LEFT/RIGHT) to adjust the volume. Refer to Figure 3-10.
S7000 Series TV Analyzer Operation Manual 3.2 Constellation diagram The constellation diagram function is used for observing the constellation diagram and the relevant parameters of the digital channel. It supports for DVB-C, DVB-T/T2 and DTMB. 3.2.1 DVB-C The interface of constellation diagram measurement refers to Figure 3-11. Figure 3-11 The interface also displays the results of MER and BER on the current channel.
S7000 Series TV Analyzer Operation Manual 3.2.1.2 Operation REFRESH Refresh constellation diagram and measurement results. SELECT Select the quadrant with red checking box. Refer to Figure 3-11. ZOOM+ Press the key to zoom in the quadrant which is selected. Refer to Figure 3-12. ZOOM- Figure 3-12 Press the key to zoom out the quadrant which is selected. NEXT>> Press this key to next page as Figure 3-13. Figure 3-13 SPECT Press the key to enter SEPCTRUM function directly.
S7000 Series TV Analyzer Operation Manual 3.2.2 DVB-T The interface of constellation diagram measurement refers to Figure 3-14. Figure 3-14 The interface also displays the results of MER, CBER and VBER on the current channel. The constellation diagram supports for the mode QPSK, 16QAM and 64QAM. The constellation diagram and MER are relevant to the carrier which is selected to measure. S7000 supports for two kinds of carriers: DATA carrier and TPS carrier.
S7000 Series TV Analyzer Operation Manual 3.2.2.2 Operation REFRESH Refresh constellation diagram and measurement results. SELECT Select the quadrant with red checking box. Refer to Figure 3-14. ZOOM+ Press the key to zoom in the quadrant which is selected. Refer to Figure 3-15. Figure 3-15 ZOOM- Press the key to zoom out the quadrant which is selected. CARRIER The key is used for selecting the display type of constellation diagram (All carriers or Sub carrier).
S7000 Series TV Analyzer Operation Manual Figure 3-17 NEXT>> Press this key to next page as Figure 3-18. Figure 3-18 SPECT Press the key to enter SEPCTRUM function directly. MER Press the key to enter MER function directly. ECHOES Press the key to enter ECHOES function directly. MEAS Press the key to enter Channel Measurement function directly. CNR Press the key to enter CNR function directly. <
S7000 Series TV Analyzer Operation Manual 3.2.3 DVB-T2 The interface of constellation diagram measurement is shown in Figure 3-19. Figure 3-19 The interface also displays the results of MER, CBER and LBER on the current channel. The constellation diagram supports QPSK, 16QAM, 64QAM and 256QAM. NOTE: The constellation diagram and the measurement parameters displayed on the interface are the data of one PLP layer. 3.2.3.1 Parameters CH, channel. Show the number of the current channel.
S7000 Series TV Analyzer Operation Manual 3.2.3.2 Operation REFRESH Refresh constellation diagram and measurement results. SELECT Select the quadrant with red checking box. Refer to Figure 3-19. ZOOM+ Press the key to zoom in the quadrant which is selected. Refer to Figure 3-20. Figure 3-20 ZOOM- Press the key to zoom out the quadrant which is selected. NEXT>> Press this key to next page as Figure 3-21. Figure 3-21 SPECT Press the key to enter SEPCTRUM function directly.
S7000 Series TV Analyzer Operation Manual <
S7000 Series TV Analyzer Operation Manual ZOOM- Press the key to zoom out the quadrant which is selected. NEXT>> Press this key to next page as Figure 3-24. Figure 3-24 SPECT Press the key to enter SEPCTRUM function directly. ECHOES Press the key to enter ECHOES function directly. MEAS Press the key to enter Channel Measurement function directly. CNR Press the key to enter CNR function directly. DTMB GPS Press the key to enter DTMB GPS function directly.
S7000 Series TV Analyzer Operation Manual 3.3 Spectrum S7000’s spectrum function can monitor the signal of CAB&TERR. Refer to Figure 3-25. Figure 3-25 The display spectrum dynamic range is up to 80dB: Adjust REF level manually and automatically. Adjust SCALE manually and automatically. Double Mark, the bottom of screen displays the marker frequency and level. Pre-Amplifier adjustment. The PEAK function can keep the maximum of all frequency.
S7000 Series TV Analyzer Operation Manual 3.3.1 Parameters CENT, central frequency (5.5MHz ~1049.5MHz). SPAN, spectrum span (1MHz ~1045MHz). START, start frequency (5MHz ~1049MHz, the start frequency can not be above the stop frequency). STOP, stop frequency (6MHz ~1050MHz, the stop frequency can not be below the start frequency). RBW, resolution bandwidth (30kHz, 100kHz, 300kHz, 1MHz, 3MHz). Scale, level scale (1dB/, 2dB/, 5dB/, 10dB/). TRC, detector mode (AVG, POS, SAMP).
S7000 Series TV Analyzer Operation Manual 3.3.2 Operation AUTO Adjust REF and SCALE automatically. HOLD/TRIG Hold or Trig the measurement. MARK?/MARK A/MARK B/MARK AB Press the key to switch the marker. Refer to Figures 3-27, 3-28 and 3-29. Users can move the marker by pressing keys (LEFT/RIGHT) to check the measurement results.
S7000 Series TV Analyzer Operation Manual Figure 3-29 PEAK Peak position finding, this function is just enable when enable the marker function. Press the key again to exit this function. MAX Press the key to open the max hold function. Refer to Figure 3-30. Figure 3-30 64 NEXT>> Press this key to next page as Figure 3-31.
S7000 Series TV Analyzer Operation Manual Figure 3-31 DISPLAY Press the key to switch Display mode. Refer to Figures 3-32, 3-33, 34 and 35.
S7000 Series TV Analyzer Operation Manual Figure 3-34 Figure 3-35 PRE-AMP CENT-SP/START-ST <
S7000 Series TV Analyzer Operation Manual 3.4 Channel Scan S7000 provides with channel scan function in order to test the flatness and amplitude of TV system quickly. Users can set up the limit value before channel scan (See Section 2: SETUP->CHANNEL->ANALOG TV/DVB-C/DVB-T LIMIT). The scan graph of current user plan is displayed as Figure 3-36.
S7000 Series TV Analyzer Operation Manual Figure 3-37 68
S7000 Series TV Analyzer Operation Manual 3.5 Tilt measurement Tilt measurement is the effective solution to check the flatness and splitter’s gain of cable system, S7000 can get levels of 16 channels and observe the measurement result and graph easily. Users can set up the tilt channel before measurement (See Section 2: SETUP->CHANNEL->EDIT TILT PLAN).
S7000 Series TV Analyzer Operation Manual SETUP MARK?/MARK A/MARK B/MARK AB Press the key to switch the marker. Refer to Figures 3-40, 3-41 and 3-42. Users can move the marker to check the measurement result. Press the key to enter the function of tilt setup. Figure 3-40 Figure 3-41 Figure 3-42 70 Press the key to enter SETUP interface directly.
S7000 Series TV Analyzer Operation Manual 3.6 CNR The interface of CNR measurement is shown in Figure 3-43. Figure 3-43 3.6.1 Parameters CH, Show the channel number of the current channel. VID FREQ, video frequency (5MHz ~1050MHz). NOISE BW, noise bandwidth (The input range is from 1MHz to 8MHz and the default values are 4.00MHz, 4.75MHz and 5.75MHz). 3.6.2 Operation HOLD/TRIG Hold or Trig the measurement. RETURN Press the key to return to the previous interface.
S7000 Series TV Analyzer Operation Manual 3.7 HUM---ANALOG TV HUM modulation is also named power hum modulation distortion, which caused by low-frequency interference of the power. Users can set up the hum frequency before measurement (See Section 2: SETUP->MEASURE->HUM). The interface of HUM measurement is shown in Figure 3-44. Figure 3-44 3.7.1 Parameters CH, Show the channel number of the current channel. FREQ, frequency (5MHz ~1050MHz). 3.7.
S7000 Series TV Analyzer Operation Manual 3.8 MOD---ANALOG TV The interface of MOD measurement is shown in Figure 3-45. Figure 3-45 3.8.1 Parameters CH, Show the channel number of the current channel. FREQ, frequency (5MHz ~1050MHz). 3.8.2 Operation HOLD/TRIG RETURN Hold or Trig the measurement. Press the key to return to the previous interface.
S7000 Series TV Analyzer Operation Manual 3.9 EVS---DVB-C The interface of EVS measurement is shown in Figure 3-46. Figure 3-46 The interface of EVS also displays MER and BER of the current channel. EVS supports DVB-C (the signal type), J.83A, J.83B and J.83C (the standard). 3.9.1 Operation REFRESH MARK?/MARK A/MARK B/MARK AB Press the key to select the marker. Refer to Figures 3-47, 3-48 and 3-49. Users can move the marker to check the measurement result. Refresh the results.
S7000 Series TV Analyzer Operation Manual Figure 3-48 Figure 3-49 PEAK RETURN Peak position finding, this function is just enable when enable the marker function. Press the key again to exit this function. Press the key to return to the previous interface.
S7000 Series TV Analyzer Operation Manual 3.10 BER---DVB-C The interface of BER is shown in Figure 3-50 Figure 3-50 In Figure 3-45, the meanings of abbreviations are as follows: abbreviations ES meaning Error seconds During 1s, there are one or more mistakes which can be corrected or not be corrected, and then ES plus1. SES Serious error seconds During 1s, if the result of the number of errors that can not be correct divided the total bits > 1.1E-3, SES plus1.
S7000 Series TV Analyzer Operation Manual 3.11 MER---DVB-T The interface of MER is shown in Figure 3-51. Figure 3-51 The function supports for the signal type DVB-T and it can measure MER up to 70 times. When the carrier type is 2K, the carrier range is from 0 to 1704. When the carrier type is 8K, the carrier range is from 0 to 6816. 3.11.1 Operation ZOOM Press the key to select the zoom levels (×1, ×2, ×3, ×4, ×5). Refer to Figures 3-51and 3-52.
S7000 Series TV Analyzer Operation Manual RETURN Press the key to return to the previous interface. Press the keys to select the single carrier. Press the keys to adjust the measurement times.
S7000 Series TV Analyzer Operation Manual 3.12 ECHOES 3.12.1 DVB-T The interface of ECHOES is shown in Figure 3-53. Figure 3-53 The function supports the signal type DVB-T and the measurement results have two display formats: Curve and List. Move the marker to check the measurement results. When select the different number in list, the marker on the curve also move correspondingly. 3.12.1.1 Operation REFRESH ZOOM+/ZOOM- Refresh the measurement results.
S7000 Series TV Analyzer Operation Manual LIST/MARK? When disable the key, users can press When enable the key, users can press keys (LEFT/RIGHT) to move marker on curve. keys (UP/DOWN/LEFT/RIGHT) to select numbers in the list and the marker on the curve also move correspondingly. Refer to Figure 3-55. Figure 3-55 RETURN Return to the previous interface. 3.12.2 DVB-T2 The interface of ECHOES is shown in Figure 3-56.
S7000 Series TV Analyzer Operation Manual 3.12.2.1 Operation REFRESH Refresh the measurement results. ZOOM+/ZOOM- Press the key to zoom in the curve. Refer to Figures 3-56 and 3-57. Figure 3-57 LIST/MARK When disable the key, users can press When enable the key, users can press keys (LEFT/RIGHT) to move marker on curve. keys (UP/DOWN/LEFT/RIGHT) to select numbers in the list and the marker on the curve also move correspondingly. Refer to Figure 3-58.
S7000 Series TV Analyzer Operation Manual CH Press the key to display the current channel information. Refer to Figure 3-59. And users can set up the current channel information. 图 3-59 82 RETURN Return to the previous interface.
S7000 Series TV Analyzer Operation Manual 3.12.3 DTMB The interface of ECHOES is shown in Figure 3-60. Figure 3-60 The function supports the signal type DTMB and the measurement results have two display formats: Curve and List. Move the marker to check the measurement results. When select the different number in list, the marker on the curve also move correspondingly. 3.12.3.1 Operation REFRESH Refresh the measurement results. ZOOM+/ZOOM- Press the key to zoom in the curve.
S7000 Series TV Analyzer Operation Manual LIST/MARK When disable the key, users can press When enable the key, users can press keys (LEFT/RIGHT) to move marker on curve. keys (UP/DOWN/LEFT/RIGHT) to select numbers in the list and the marker on the curve also move correspondingly. Refer to Figure 3-62. Figure 3-62 CH RETURN 84 Press the key to display the current channel information. Refer to Figure 3-63. And users can set up the current channel information.
S7000 Series TV Analyzer Operation Manual 3.13 DTMB GPS S7000 supports the function of DTMB GPS. Please connect the antenna and GPS module. After S7000 recognizes the GPS module successfully, the interface of DTMB GPS will be shown as Figure 3-64. Figure 3-64 S7000 can search satellite information and save the measurement as a file. The instrument saves the file one time per second. You can look over the file that you saved in File Management and export the file using USB device.
S7000 Series TV Analyzer Operation Manual 3.13.1 Operation START The key is enabled when GPS module attached to S7000 is locked and DTMB signal is locked. Press the key to pop up a message of inputting the name of a file. S7000 will save the measurement as a file(refresh one time per second) after inputting the name. And the key status is STOP, refers to figure 3-65. Press the key to switch the measurement. Figure 3-65 The files format is .
S7000 Series TV Analyzer Operation Manual 3.14 DVB-T2 INFO---DVB-T2 The channel parameters are recognized automatically. Users can read the parameters on the interface. Refer to Figures 3-66 and 3-67. Figure 3-66 Figure 3-67 3.14.1 Operation L1 INFO Display the parameters information of L1 layer. PLP INFO Display PLP list and the parameters relevant to PLP. ECHOES Press the key to enter ECHOES function directly. RETURN Return to the previous interface.
S7000 Series TV Analyzer Operation Manual 4.
S7000 Series TV Analyzer Operation Manual Main menu of satellite system is shown in Figure 4-1. Figure 4-1 The function icons of the main menu are defined as follows: Press ---- Measurement ---- Constellation diagram measurement ---- Spectrum analysis ---- Dish Align ---- DiSEqC keys (LEFT/RIGHT) to select the relevant function icons, and you can press key (ENTER) to enter the relevant interfaces. S7000 will display the satellite name in use on the title bar, as shown in Figure 4-1.
S7000 Series TV Analyzer Operation Manual Figure 4-2 Press F6 (SAVE) to save the latest setup and press key (ESC) or key (CH INFO) to return. For satellite signal testing, LNB need the power feed by receiver or analyzer. For power feed setup, please see Section 2: SETUP-> INTF. -> LNB POWER. The interface is as Figure 4-3. Figure 4-3 Press keys (UP/DOWN) and key (ENTER) to switch the feed options, and press key (SETUP) again to return.
S7000 Series TV Analyzer Operation Manual 4.1 Measurement Measurement of satellite transponder(DVB-S) as shown in Figure 4-4, this function can test Power, MER, CBER and VBER. Figure 4-4 4.1.1 Parameters TP, name of satellite transponder. User can input a transponder name directly or press (UP/DOWN) to switch transponder. SAT-IF, the output frequency from LNB, frequency range is from 950MHz to 2150MHz.
S7000 Series TV Analyzer Operation Manual 4.1.2 Operation VIEW Press the key to switch the display between power, MER, CBER or VBER. CONS Shortcut key to Constellation function. DISH Shortcut key to Dish Align function. DiSEqC Shortcut key to DiSEqC function. SPECT Shortcut key to Spectrum function. CNR Shortcut key to CNR function. Shortcut key to power feed control function. 4.1.
S7000 Series TV Analyzer Operation Manual 4.2 Constellation diagram(DVB-S/S2) Constellation diagram function as shown in Figure 4-5. Figure 4-5 Constellation function can display both constellation diagram and MER, BER measurement results. Modulation mode (QPSK, 8PSK) can be support. 4.2.1 Parameters TP, name of satellite transponder. User can input a transponder name or press switch transponder. SAT-IF, the output frequency from LNB, frequency range is from 950MHz to 2150MHz.
S7000 Series TV Analyzer Operation Manual 4.2.2 Operation REFRESH Refresh the measurement result and the constellation diagram by manual. SPECT Shortcut key to Spectrum function. DISH Shortcut key to Dish Align function. DiSEqC Shortcut key to DiSEqC function. MEAS Shortcut key to Measurement function. CNR Shortcut key to CNR function. 94 Shortcut key to power feed control function.
S7000 Series TV Analyzer Operation Manual 4.3 Spectrum Spectrum analyzer function allows the user to capture the satellite signals quickly. As shown in Figure 4-6. Figure 4-6 Display dynamic is range from 8dB to 80dB. PRE-AMP, S7000 has a built-in pre-amplifier Default is closed. MAX, max hold, this function can display the max hold curve of each frequency. DRIVE, satellite spectrum analyzer support easy operation to drive positioner. DISPLAY, S7000 supports four display modes.
S7000 Series TV Analyzer Operation Manual 4.3.1 Parameters CENT, centre frequency range is from 955MHz to 2145MHz. If the input frequency is above the range, S7000 will identify if the input frequency is valid C band or Ku band, if valid, S7000 will calculate the SAT-IF automatically. For example: Input 1938MHz, 1938MHz is in centre frequency range, this value is valid. Input 12538MHz, this is a valid transponder frequency in Ku band.
S7000 Series TV Analyzer Operation Manual Figure 4-8 97
S7000 Series TV Analyzer Operation Manual 4.3.2 Operation AUTO Automatically adjust the level scale and reference level to get the best view. HOLD/TRIG Hold or Trig the measurement. MARK?/MARK* Press this key to enable frequency marker, and then user can move the marker by press keys (LEFT/RIGHT), as shown in Figure 4-8, press this key again to exit this function. PEAK Peak position finding, this function is just enable when enable the marker function.
S7000 Series TV Analyzer Operation Manual Figure 4-11 Figure 4-12 Figure 4-13 99
S7000 Series TV Analyzer Operation Manual PRE-AMP Press the key to take on/off the preamplifier. When enable it, an icon ( bottom status bar. MEAS Shortcut key to satellite transponder measurement function. DRIVE Press this key will enable the positioner drive function. And then user can drive the positioner by keys (LEFT/RIGHT), the positioner will be drived in seconds. DiSEqC Shortcut key to DiSEqC function. <
S7000 Series TV Analyzer Operation Manual 4.4 DISH Dish alignment function as shown in Figure 4-14. User can use this function to align dish antennas. Figure 4-14 NOTE: Dish alignment function supports at most 10 transponders. If user select more than 10 transponders, S7000 only measure the first 10 enabled transponders. Otherwise, S7000 measures the whole enabled transponders. Figure 4-14 displays 6 transponders. S7000 measures the quality and strength of transponders to align the dish.
S7000 Series TV Analyzer Operation Manual The bellowing parameters may be useful for dish align: S7000 can setup position information by manual or USB-GPS module(Option). Refer to Figure 4-16. Figure 4-16 Azimuth (0-180°). Angle of elevation (0-90°). Angle of polarization. Dish alignment function display the testing result in percentage (0%-100%) with different colors as shown in Figure 4-17.
S7000 Series TV Analyzer Operation Manual 4.4.1 Operation SAT, satellite name and longitude. User can switch between enabled satellites plan. Refer to Figure 4-18. Figure 4-18 FIXED/NORMAL DiSEqC Shortcut key to DiSEqC function. SPECT Shortcut key to spectrum function. MEAS Shortcut key to measurement function. DRIVE Press this key will enable the positioner drive function. And then user can drive the positioner by keys (LEFT/RIGHT), the positioner will be drived in seconds.
S7000 Series TV Analyzer Operation Manual MUTE Press this key to make S7000 in mute state, this will shut down the buzzer. Refer to figure 4-20. Figure 4-20 Switch the transponder/drive positioner/adjust buzzer volume. Press these keys to switch the satellite when SAT is highlighted. Switch the transponder. Shortcut key to power feed control function.
S7000 Series TV Analyzer Operation Manual 4.5 DiSEqC DiSEqC (Digital Satellite Equipment Control) is a communication protocol between the satellite receiver and the devices. S7000 supports DiSEqC 1.0, 1.1, 1.2, 2.X. DiSEqC & SaTCR control function as shown in Figures 4-21 and 4-22.
S7000 Series TV Analyzer Operation Manual 4.5.1 Parameters DiSEqC (Digital Satellite Equipment Control) command list: Class Command General Switch Positioner Parameter RESET ---- STANDBY POWER ON SATA/B DiSEqC1.0 SWITCH DiSEqC1.1 SWITCH HALT DISABLE LIMITS SET LIMIT EAST SET LIMIT WEST DRIVE EAST SEC DRIVE EAST STEPS DRIVE WEST SEC DRIVE WEST STEPS STORE POSITION GOTO POSITION GOTO X.
S7000 Series TV Analyzer Operation Manual 4.5.2 Operation SaTCR/DiSEqC Press this key to switch between DiSEqC and SaTCR. Press In DiSEqC function, press Press this key to send command. Shortcut key to power feed control function. keys (UP/DOWN) to select command/parameter. keys (LEFT/RIGHT) to adjust command parameters. NOTE: 1. DiSEqC&SaTCR command sending function is disabled, when LNB power is off or in use. 2. When sending DiSEqC&SaTCR command, any key’s operation is not active.
S7000 Series TV Analyzer Operation Manual 4.6 CNR The interface of CNR measurement is shown in Figure 4-23. Figure 4-23 4.6.1 Parameters TP, name of satellite transponder. User can input a transponder name directly or press (UP/DOWN) to switch transponder. TP –FREQ, transponder frequency, S7000 supports two frequency bands: DL-Ku band (10.75GHz~12.75GHz). DL-C band (3.4GHz~4.2GHz). BW, bandwidth (1.4 MHz ~60.8 MHz). 4.6.2 Operation HOLD/TRIG Hold or Trig the measurement.
S7000 Series TV Analyzer Operation Manual 5.
S7000 Series TV Analyzer Operation Manual 5.1 Brief introduction TS analyzer module supports DVB and ATSC standard TS analysis including RealTime TS and Offline TS and also IPTV data. Subfunctions are as follows: RealTime Decoder, Recorder, Channel Edit, Replay, Basic Information, TR101 290, PID Viewer, Program Information, PCR, Program List, PSI/SI, Data Capture and TR101 290 Parameters Setting. TS function user guide is provided in RF input case.
S7000 Series TV Analyzer Operation Manual 5.2 RealTime Decoder Figure 5-1 This subfunction can decode the program according to the input source of RF, ASI or IPTV. Program information are shown in the list, including program number, CA, service name, provider, service type, video stream type and the video resolution. If the information is not provided in the stream, ‘---’is shown. Video and audio PID and bitrate are shown of the selected program.
S7000 Series TV Analyzer Operation Manual 5.2.1 Description SID: the program number in 10 or 16 system according to the Setup. CA: Service Name: the service name of the program, ‘---’is displayed if the description is not exist. Provider: the provider of the program, ‘---’is displayed if the description is not exist. Service Type: the brief description of service type of the program.
S7000 Series TV Analyzer Operation Manual 5.3 Channel Edit Figure 5-3 5.3.1 Description To edit channel information briefly, shown as Figure 5-3.
S7000 Series TV Analyzer Operation Manual 5.4 Recorder Figure 5-4 5.4.1 Description To input recorder file name in TS format. 5.4.2 Operation Take the input name ‘10’ for example, the recording file name is ‘10.ts’, and press key (ENTER) to start recode. Refer to Figure 5-5. If the ‘10.
S7000 Series TV Analyzer Operation Manual 5.4.3 Description To display the recording information, including the file name, the recoded file size, left space of the U disk. NOTE: The recorder files should be saved in the USB device.
S7000 Series TV Analyzer Operation Manual 5.5 Replay Figure 5-6 5.5.1 Description To list maximum 200 files (the file size is less than 3GB) with TS or TRP format. Files name and files size are displayed. 5.5.2 Operation To select a file. For example, the file ‘bbc_TV&Radio.ts’ is selected. Press program information. Refer to Figure 5-7.
S7000 Series TV Analyzer Operation Manual 5.5.3 Description To display the information of Replay, including SID, CA, ServiceName, Provider, ServiceType, VideoType, Resolution, Video PID, Video Bitrate, Audio PID and Audio Bitrate. 5.5.4 Operation To switch full video screen and small video screen if decoding.
S7000 Series TV Analyzer Operation Manual 5.6 Basic Information Figure 5-8 5.6.1 Description This subfunction shows you the basic information of the stream. TS RATE: Describe the stream transport rate in a second (Mb/s). TS STRUCTURE: Describe the components of the TS and the rate of every component. OTHER INFO: Describe the other information of the stream. LENGTH: The transport length in bytes. PROG COUNT: Show the total programs. TS ID: Stream ID.
S7000 Series TV Analyzer Operation Manual 5.6.2 Operation BASIC INFO EVENT INFO/TR101 290 To execute the BASIC INFO subfunction, shown as Figure 5-8. To execute the TR101 290 subfunction. Press this key continuously to switch between TR101 290 and EVENT INFO. Refer to Figure 5-9 and Figure 5-10. PID VIEW PROG GRAP/PROG INFO To execute PID VIEW subfunction. Refer to Figure 5-11. To execute the PROG INFO subfunction. To switch PROG INFO and PROG GRAP when this key is continuously pressed.
S7000 Series TV Analyzer Operation Manual 5.7 TR101 290 Figure 5-9 5.7.1 Description The first table lists a basic set of parameters which are considered necessary to ensure that the TS can be decoded. The second table lists additional parameters which are recommended for continuous monitoring. The third table lists optional additional parameters which could be of interest for certain applications. Parameter buff is not included because of the limit of hardware capacity. 5.7.
S7000 Series TV Analyzer Operation Manual 5.7.3 Description It describes the detailed information, including the record time, the standard number. 5.7.4 Operation To reset to monitor the stream and clear the result. To page up and page down.
S7000 Series TV Analyzer Operation Manual 5.8 PID View Figure 5-11 5.8.1 Description It describes the information with section, simplified information, value, PID and the CR of every PID of the stream. Section: the PID type. PID: the PID value. CR: the bitrate of the PID. The Value and CRare calculated within a second. 5.8.2 Operation 122 To page up and page down.
S7000 Series TV Analyzer Operation Manual 5.9 Program Information Figure 5-12 5.9.1 Description This function parses the information from audio and video ES. It supports MPEG-1/2/4, H.264 video format and MEPG-1/2/4, AAC audio format. At most two audio information can be displayed. It lists the SID, CA, bitrate, service name, provider, service type in the bellow list. And the video/audio information of selected program is above. The parameters may be different according to the audio/video format.
S7000 Series TV Analyzer Operation Manual 5.9.3 Description To display the program information with SID, CA, bitrate, service name, provider, service type. The yellow curve is the video BW rate curve if video information included in the program. The green curve is the first audio BW curve if audio information included in the program. The abscissa is on behalf of the rate of the current time, and the ordinate is on behalf of BW percent of the program.
S7000 Series TV Analyzer Operation Manual 5.10 PCR Figure 5-14 5.10.1 Description To display the PCR accuracy and PCR interval of the selected program. Refer to Figure 5-14. Figure 5-15 shows the detailed PCR information. If the PCR does not exist, ‘---’is displayed. Different programs can have the same PCR and every program can have its PCR. PCR accuracy of selected program is within ±500 ns and PCR interval of the selected program is from 0 ms to 40 ms. The scale can be setted in PARAM SET function.
S7000 Series TV Analyzer Operation Manual 5.10.3 Description Figure 5-15 shows the detailed PCR information, including PCR PID, min accuracy, max accuracy, min interval, and max interval. If the PCR does not exist, ‘---’is displayed. 5.10.4 126 Operation To select a program.
S7000 Series TV Analyzer Operation Manual 5.11 Program List Figure 5-16 5.11.1 Description To list the programs information in ascending order of frequency of the current transport network. If it’s cable system, it lists program number, frequency, CA, service name, provider, service type, modulation type/SR(MS/s). If it’s satellite system, it lists program number, frequency, CA, service name, provider, service type, modulation type/SR(MS/s), and the polarization.
S7000 Series TV Analyzer Operation Manual 5.12 PSI/SI Figure 5-17 5.12.1 Description Figure 5-17 shows the PSI/SI information of the stream. The left table lists the tables such as PAT, PMT, CAT and the right lists the detailed information according to the select table. 5.12.2 Operation To select a table and show the detailed information in right table. To select the table. To select a table and show the detailed information in right table.
S7000 Series TV Analyzer Operation Manual 5.13 Capture Figure 5-18 5.13.1 Description To capture data according to the selected PID and display the data in the right box.
S7000 Series TV Analyzer Operation Manual 5.13.
S7000 Series TV Analyzer Operation Manual 5.14 Parameter Setting Figure 5-19 5.14.1 Description To set alarm parameters.
S7000 Series TV Analyzer Operation Manual 6.
S7000 Series TV Analyzer Operation Manual 6.1 IPTV S7000 will recognize and display the information of the TS when the network has the TS. Refer to Figure 6-1. Figure 6-1 INFO Press this key, you can look over the information of TS. Refer to Figure 6-2.
S7000 Series TV Analyzer Operation Manual TS MEAS The key is enabled when S7000 displays the information of IPTV. You can press the key to enter interface of TS Monitor & Analysis and the status bar of S7000 displays: IP TV. Refer to Figure 6-3. Figure 6-3 Users can record and replay the current TS (Section 5: Monitor & Analysis). 134 RETURN You can press the key to return the previous interface.
S7000 Series TV Analyzer Operation Manual 7.
S7000 Series TV Analyzer Operation Manual Press key (HOME) to return to main menu and press F6 (FILES) to File Management. S7000 provides internal memory space to store measurement data in LEVEL measurement, Channel Scan, Constellation function. The test result can be saved as JPG format or data format file. 7.1 Picture File 7.1.1 Operation PICTURE/DATA Press the key to view the list of all saved picture files. The files are identified by their name, date, time, as Figure 7-1.
S7000 Series TV Analyzer Operation Manual VIEW SELECT ALL/CLEAR Press this key and the picture file view and file name will appear in full screen. Press any key (except key (HOME)) to return to file list window. Press this key to select all files and all files are with ‘√’ indicator, as Figure 7-2. At this time, this key will be changed to CLEAR. Press this key to de-select all files and all files are without ‘√’ indicator.
S7000 Series TV Analyzer Operation Manual Note: This key is disabled if no file is highlighted and the instrument does not recognize the USB device. NEXT>> Press this key to next page as Figure 7-4. Figure 7-4 SORT Press this key to sort the file in list. The sort key words include Ascend, Descend, Name and Date as Figure 7-5.
S7000 Series TV Analyzer Operation Manual RENAME Press this key and rename dialog box will appear, use the alphanumeric keypad to enter a new name and confirm, as Figure 7-6. Figure 7-6 <
S7000 Series TV Analyzer Operation Manual 7.2 Data File 7.2.1 Operation DATA/PICTURE Press this key to view the list of all saved data files. The files are identified by their name, type, date, time and operator, as Figure 7-7. Figure 7-7 Press keys (UP/DOWN) to highlight the file and select related key to VIEW, DELETE, EXPORT, SORT, RENAME and so on. Refer to Figure 7-7. VIEW Press this key to view the data file. As some file includes both graph and data.
S7000 Series TV Analyzer Operation Manual Figure 7-8 To select (with ‘√’ indicator )/ de-select single file(without ‘√’ indicator ), please press the file and press key (ENTER), as Figure 7-9. keys (UP/DOWN) to Figure 7-9 DELETE Highlight the file and press this key the dialog box ‘Delete selected file(s)’ will appear. Select ‘YES’ to delete the file and ‘NO’ to give up. Note: This key is disabled if no file is highlighted.
S7000 Series TV Analyzer Operation Manual NEXT>> Press this key to next page as Figure 7-10. Figure 7-10 SORT Press this key to sort the file in list. The sort key words include Ascend, Descend, Name, Type, Date and Operator as Figure 7-11.
S7000 Series TV Analyzer Operation Manual RENAME Press this key and rename dialog box will appear, use the alphanumeric keypad to enter a new name and confirm, as Figure 7-12. Figure 7-12 <
S7000 Series TV Analyzer Operation Manual 8.
S7000 Series TV Analyzer Operation Manual 8.
S7000 Series TV Analyzer Operation Manual Echo Pattern DVB-T2 Measurement Modulation Type Power Level Range Power Resolution Power Level Accuracy MER Measurement MER Accuracy CBER LBER Constellation Echo Pattern ATSC Measurement Modulation Type Power Level Range Power Resolution Power Level Accuracy MER Measurement MER Accuracy BER Constellation DTMB measurement Carriers Power Level Range Power Resolution Power Level Accuracy MER Measurement MER Accuracy BER Constellation Echo Pattern DVB-S/S2 measurement M
S7000 Series TV Analyzer Operation Manual Video Video Resolution Audio CAM Module TS-ASI Input And Output TS Record TS analysis Interface DVB-ASI Interface DVB-ASI Clock DVB-ASI Max Data Rate DVB-ASI Output Signal Level DVB-ASI Return Response DVB-ASI Input Level Real time Decoder TR101290 Monitor Base Information PID List Program Information PCR Monitor PSI/SI List Program Info MPEG2/4, H.
S7000 Series TV Analyzer Operation Manual Working Time Remote Feeding 22 kHz Control Signals Dimension (W×H×L) Weight Working Temperature Storage Temperature Option DVB-CI ASI IN/OUT TS Analysis DVB-T2 IPTV 148 >5 Hours 5/13/15/18/24 V, Max. 5W DiSEqC 1.2 and SaTCR 245mm×194mm×105mm around 2.
S7000 Series TV Analyzer Operation Manual 8.
S7000 Series TV Analyzer Operation Manual 8.3 Function of S7000 1 2 3 4 5 6 7 8 9 10 Function ANALOG TV、FM DVB-C DVB-T DVB-S/S2 DVB-T2 DTMB CAM ASI TS Analysis IPTV S7000 ■ ■ ■ ■ □ □ □ ■ □ □ S7000L ■ □ □ □ △ △ × × □ □ The symbols are shown as following: ■:Have this function. □:The function can be used by obtaining the software rights. △:You must upgrade the hardware first and then the function can be used by obtaining the software rights. ×:Nonsupport.