System information
S7000 Series TV Analyzer Operation Manual
47
3.1.2 DVB-C
The interface of DVB-C Channel Measurement refers to Figure 3-5. It can measure Power
level/MER/PRE-BER/POST-BER and so on.
Figure 3-5
3.1.2.1 Parameters
CH, Show the channel number of the current channel.
FREQ, frequency (5MHz ~1050MHz).
BW, bandwidth (1MHz ~50MHz).
MODE, modulation type.
When STD is J.83A and J.83C, MODE is 16QAM, 32QAM, 64QAM, 128QAM and 256QAM;
When STD is J.83B, MODE is 64QAM and 256QAM;
When STD is J.83D, MODE is 8VSB and 16VSB.
SR, symbol rate.
When STD is J.83A, J.83B and J.83C, SR range is from 4 MS/s to 7 MS/s;
When STD is J.83D, the fixed SR is 10.762 MS/s.
STD, standard (J.83A, J.83B, J.83C, J.83D).
3.1.2.2 Operation
VIEW Press the key to switch the display between Power level/MER/PRE-BER/POST-BER when the
current channel type is DVB-C.
CONS Press the key to enter Constellation diagram function directly.
BER Press the key to enter BER function directly.
EVS Press the key to enter EVS function directly (The key works when STD is J.83A, J.83B and J.83C.).
SPECT Press the key to enter SEPCTRUM function directly.
CNR Press the key to enter CNR function directly.