IBL Series - Projector Lift Models 1522, 2424 Installation Manual READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION tel: 303.412.0399 fax: 303.412.9346 www.displaydevices.com tech@displaydevices.com 5880 Sheridan Blvd.
IP025-001 V3 IBL Lift Series Installation Contents 07/05 Important Installation Notes 3 Lift Placement 4 Installation 4 Control Settings 5 Plenum Enclosure Assembly 6 Physical Installation – top mounting 7 Physical Installation – side mounting 9 Connecting Power 11 Projector Mounting 13 Cabling the Lift 13 Ceiling Closure 15 Final Adjustments 17 Specifications 17 Lift Removal 18 Maintenance and Safety 18 Emergency Operation 19 Remote Control Operation and Programming 20
IP025-001 V3 IBL Lift Series Installation Thanks for purchasing a Display Devices lift product. We’re sure your customer will enjoy this lift for years to come. Our products are designed to be maintenance-free, saving you future service time. If you experience any difficulties, please contact us at 303-412-0399. Thank you for your support. Important Installation Notes Before starting… Read all instructions before installation.
IP025-001 V3 IBL Lift Series Installation Lift Placement and Location Verify the projector’s lens offset from the center of the projector and center the lens onto the center of the projection screen. If your lens is offset from the center of the projector, the lift should have the same opposing offset to center. Ensure that the centerline of the lens remains aligned with the centerline of the screen.
IP025-001 V3 IBL Lift Series Installation CONTROL SETTINGS Prior to the physical installation, you must perform the following steps: 1. Be sure that there is no power attached when setting the DIP switches. 2. Set the DIP switches on the control box before you install the lift in the ceiling. Refer to the chart below for proper configurations. 3. Dip switches are located under the small access panel on the Control Box attached to the lift frame. Use a 1/16” hex drive to open. 4.
IP025-001 V3 IBL Lift Series Installation PHYSICAL INSTALLATION Plenum Enclosure Assembly This assembly is shipped as a kit. Layout all components as follows and assemble based on the steps below.
IP025-001 V3 IBL Lift Series Installation PHYSICAL INSTALLATION TOP-MOUNTING Top mounting is typically used when installing the lift into a false ceiling (grid tile) or an exposed unfinished ceiling. We recommend you install mounting hardware into a structural channel. Example – Top Mounting Structural channel provides flexibility for adjusting the lift front-to-rear and side-to-side. • All hardware should be at least in 3/8” (M10) diameter.
IP025-001 V3 IBL Lift Series Installation PHYSICAL INSTALLATION TOP-MOUNTING 1.) Plenum installations - attach the plenum enclosure to the 8 studs on the lift’s upper frame. Add flat washer, split lock washer and 7/16” nuts – tighten. 2.) Before you begin, be sure the threaded rods have a nut and split washer above the lift frame, and a flat washer and nut below the frame. These can be temporarily held in place with tape or chewing gum. 3.) Raise the lift into position and add hardware.
IP025-001 V3 IBL Lift Series Installation PHYSICAL INSTALLATION SIDE-MOUNTING Side-mounting is typically used when installing the IBL-1522 lift between 16” on-center floor joists. NOTE for Retrofit installations with the IBL-1522: Cut hole opening – 21”l x 14.5”w. 1.) Determine the top height of lift/enclosure and mark the top position on the joists. Mark the front and rear position of the lift on the joists – both the left and right sides. 2.
IP025-001 V3 IBL Lift Series Installation 7.) Be sure the lift is centered left-to-right, then tighten the mounting bracket hardware. 8.) If you are using the plenum enclosure, adjust the height by loosening the (4) Philips Head Screws, slide the enclosure box to the proper vertical height, and retighten. 9.) Raise the enclosure up into and through the ceiling hole.
IP025-001 V3 IBL Lift Series Installation Lift Connections / Connecting Power 1.) Verify voltage at the outlet/power source for the projector/lift. You can now connect the lift’s power cord to a properly rated electrical circuit in the ceiling near the lift. 2.) Plug the remote control unit cable into either of the two 9 pin control remote ports on the side of the control box. 3.) Tighten the cable clamps / strain relief connectors, if required. 4.
IP025-001 V3 IBL Lift Series Installation Caution! Make sure all tools, cables, and body parts are clear of the lift before pushing the UP button. 10.) With the hand-held remote control, press the UP button to send the lift to its fully UP, home position. Refer to the Remote Control Operation and Programming section for details on how to operate program the lift’s functions.
IP025-001 V3 IBL Lift Series Installation Projector Mounting 1.) The lift is shipped with the projector mounting adapter attached. Remove it from the lower frame of the lift, if you have not already done so. 2.) Invert your projector and attach the mounting adapter to the bottom of the projector with the proper hardware. 3.) Find the projector’s center of gravity using a dowel. 4.) Attach the adapter to the lift with the projector’s center of gravity under the vertical wire rope of the lift.
IP025-001 V3 IBL Lift Series Installation Attaching the Cables 1.) Using the hand-held remote, lower the lift down to the MAINTENANCE position. See the enclosed remote control instructions for information about how to program this position. The signal, power, and control cables can now be routed into the cable management clips on sides of the scissor assembly. 2.) The lift is shipped with a sample cable in the clips. Attach your cables in a likewise manner.
IP025-001 V3 IBL Lift Series Installation Ceiling Closure 1.) If you are using a 2424 model, attach the CTB Sliders to the front and rear of the lower lift frame. Use ¼-20 hex head bolts, flat washer, split washer and nut. Do not tighten. 2.) Attach the left and right CTB Brackets to the CTB Sliders using ¼-20 hex head bolts, flat washer, split washer and nut. Do not tighten. 3.) Determine the length of the threaded rod and cut to length needed.
IP025-001 V3 IBL Lift Series Installation 9.) Raise the lift up – keep a close eye as the lower frame enters the enclosure/hole. Center the closure panel left-to-right and front-to-rear. Tighten the CTB Bracket and Slider hardware when completed.
IP025-001 V3 IBL Lift Series Installation Final Adjustments Operate the lift up and down several times to verify all adjustments and ensure proper operation. Raise the lift to its home position with the UP button (in MANUAL mode) slowly, carefully, and intermittently. Observe the cables rigged to the sides of the lift carefully and watch for any problems. Bring the lift down with the DOWN button, and again watch for any problems. Adjust the closure system as needed.
IP025-001 V3 IBL Lift Series Installation Lift Removal 1. Disconnect all cables from the projector. It may be necessary to remove all cabling 2. from the cable management clips on the side of the lift if disconnects were not installed. 3. Remove the Ceiling Closure Panel. 4. Remove the projector from the lift. 5. Raise the lift into the closed position. 6. Disconnect the AC power and remote control cables. 7. Support the lift with an appropriate support system. 8.
IP025-001 V3 IBL Lift Series Installation Emergency Operation If your lift has traveled below the service position, and activated the lower limit safety switch, you will need to refer to the Remote Control Operation and Programming section and/or follow the steps below: 1. Remove the back cover of the handheld remote control case, or remove the switch plate from the wall box. 2. Press and hold the EMERGENCY button in the circuit board, press the UP button and release, then release the EMERGENCY button.
IP025-001 V3 IBL Lift Series Installation Hand-held Remote Control Unit Model # S10018 Front Back UP DOWN STOP EMERGENCY – accessible only with back cover removed SET These two bottoms are accessed with a small point OVERRIDE The Display Devices Hand-held Remote Control Unit is a versatile, multi-functional programmable remote for lift operation. The UP button moves the lift to the home position in AUTOMATIC mode, and raises the unit intermittently on command in MANUAL mode.
IP025-001 V3 IBL Lift Series Installation HOW DO I? Program the lift to MANUAL MODE 1. Use a small point (straightened paperclip) to press and hold the OVERRIDE button then press the UP button. Release UP, then release OVERRIDE. 2. Test the unit by pressing the DOWN button. It should move only when the button is depressed. The lift will stop when the button is released. .
IP025-001 V3 IBL Lift Series Installation HOW DO I… Set the SHOW position This is the intermediate level for “on screen” projection. 1. Program the remote to MANUAL MODE - Press and hold the OVERRIDE button then press the UP button. Release UP then release OVERRIDE. 2. Lower the lift with the DOWN button to its desired projection position. 3. To program the remote to the SHOW position: press and hold the SET button then press the UP button. Release UP then release SET. 4.
IP025-001 V3 IBL Lift Series Installation HOW DO I? Set the SERVICE / MAINTENANCE position This is lower than the SHOW setting, bringing the lift to a level making maintenance, service, lamp and filter changes, and projector adjustments easier. 1. Program the remote to MANUAL MODE - Press and hold the OVERRIDE button then press the UP button. Release UP, then release OVERRIDE. 2. Lower the lift with the DOWN button to its desired position for the easiest access for maintenance and repair. 3.
IP025-001 V3 IBL Lift Series Installation HOW DO I? Program the remote to AUTOMATIC MODE 1. Press and hold the OVERRIDE button, followed by the STOP button. Release the STOP then OVERRIDE buttons. In the AUTOMATIC MODE, the lift will automatically descend to the proper show level, rise to the HOME position, and descend to its lower limit service and maintenance.
IP025-001 V3 IBL Lift Series Installation HOW DO I… Recover Lift from LOWER LIMIT SWITCH ACTIVATION When the Lift is lowered beyond its lower limit or Service/Maintenance position, a small trip lever activates a safety shut-off on the lower limit switch. It is located on the between the control box and scissors. If the lift will not respond to any command buttons and the LED on the remote and control box blinks seven times proceed with the following: 1. 2. 3. 4. 5. 6.
IP025-001 V3 IBL Lift Series Installation 7. 8. 9. Press both the OVERRIDE and SET buttons at the same time. This will reset the electronic lower limit switch. Return the remote to AUTOMATIC MODE (OVERRIDE + STOP). Press the UP button, and allow the lift to travel up to its home position. *Hold in the EMERGENCY OVERRIDE button (the LED will stop blinking). Keep the EMERGENDY OVERRIDE button held, then press and hold the UP button. Keep both buttons held until the lift has moved six inches.
IP025-001 V3 IBL Lift Series Installation Summary of the Remote Control Functions The OVERRIDE and SET buttons are hidden on the back of the remote control. The lower button is OVERRIDE and the top button is SET. A straightened paper clip or similar device will be needed to activate them. When using the OVERRIDE and SET buttons, these buttons must be pressed first and released last in the sequence. To set the normal show position, press and hold SET, press and release UP, and then release SET.
IP025-001 V3 IBL Lift Series Installation SETTING MAINTENANCE AND SHOW POSITIONS Put the Lift into Manual Mode Press OVERRIDE & UP Press DOWN to lower lift to desired Maintenance position (lift will stop when button in released) Press DOWN to lower lift to desired Show position (lift will stop when button is released) Set Maintenance position Press SET & STOP Set Show position Press SET & UP Return to AUTO mode Press OVERRIDE & STOP Press UP button, lift should travel to home Return to AUTO mode Pres
07/05 29 LED SET UP O/R DOWN SAFETY O/R STOP 22 AWG for cable runs up to 100 feet 20 AWG for cable runs that are 100 to 500 feet NOTE: O/R = OVERRIDE Do not connect or short any wires to Pin 8 or 9 except Safety Override Button 9 Orange - Safety Switch O/R (5ma draw) 9 Brown +5V 7 Purple – LED (20ma draw) 6 White - (Ground) 5 Yellow – O/R (5ma draw) 4 Blue - SET (5ma draw) 3 Green - STOP (5ma draw) 2 Red - DOWN (5ma draw) 1 Black – UP (5ma draw) Digital Remote Interface Schematic IP025-
IS THE LED ACTIVE UPON POWER UP? after 10 second 07/05 30 6 BLINKS: Safety switch triggered – call DDI for instructions 5 BLINKS: Low AC voltage.
IP025-001 V3 IBL Lift Series Installation Warranty This product is warranted against defects in material and labor for 12 months from the date of shipment from Display Devices, Inc. Unit must not exhibit previous alterations or repairs except those performed by an authorized Display Devices dealer, distributor or factory service center. Exclusions: Routine maintenance, normal wear and tear, misuse, improper operation or installation, neglect, abuse or acts of nature. Fax or mail to: Display Devices, Inc.
IP025-001 V3 IBL Lift Series Installation Help us help you! We value your feedback about our products. Any input you can provide will help us design and build better products for you. Please take a few minutes to answer the following questions. Use a 1 to 10 scale with 1 being poor to 10 being excellent. When complete, fax it back to us at 303-412-9346.