Diagnostic Codes
CMW
91 0 red accelerator pedal or lever
position sensor 1
data valid, but above normal operational
range - most severe level
91 2 red accelerator pedal or lever
position sensor 1
data erratic, intermittent or incorrect
91 19 red SAE J1939 multiplexed
accelerator pedal or lever
sensor system
received network data in error
91 9 red SAE J1939 multiplexed
accelerator pedal or lever
sensor system
abnormal update rate
95 16 amber fuel filter differential pressure data valid but above mornal operating
range, moderately severe
97 15 amber,
blinking
water in fuel indicator data valid but above normal operating
range, least severe level
97 3 amber water in fuel indicator sensor
circuit
voltage above normal or shorted to high
source
97 4 amber water in fuel indicator sensor
circuit
voltage below normal or shorted to low
source
100 3 amber engine oil rifle pressure 1
sensor
voltage above normal or shorted to high
source
100 4 amber engine oil rifle pressure 1
sensor
voltage below normal or shorted to low
source
100 18 amber engine oil rifle pressure data valid but below normal operationg
range - moderately severe level
100 1 red engine oil rifle pressure data valid but below normal operating range
- most severe level
100 2 amber engine oil rifle pressure data erratic, intermittent or incorrect
101 16 amber crankcase pressure data valid but above normal operating
range, moderately severe level
101 0 red crankcase pressure data valid but above normal operational
range, most severe level
101 3 amber crankcase pressure voltage above normal or shorted to high
source
101 4 amber crankcase pressure voltage below normal or shorted to low
source
101 2 amber crankcase pressure data erratic, intermittent, or incorrect
SPN FMI Warning
Color