Diagnostic Codes
CMW
101 15 amber
blinking
crankcase pressure data valid but above normal operating
range, least severe level
102 3 amber intake manifold 1 pressure
sensor
voltage above normal or shorted to high
source
102 4 amber intake manifold 1 pressure
sensor
voltage below normal or shorted to low
source
102 2 amber intake manifold 1 pressure data erratic, intermittent, or incorrect
103 16 amber turbocharger 1 speed data valid but above normal operating
range, moderately severe level
103 18 amber turbocharger 1 speed data valid but below normal operating
range, moderately severe level
103 15 amber turbocharger 1 speed data valid but above normal operating
range, least severe level
105 3 amber intake manifold 1
temperature sensor
voltage above normal or shorted to high
source
105 4 amber intake manifold 1
temperature sensor
voltage below normal or shorted to low
source
105 0 red intake manifold 1
temperature
data valid but above normal operational
range, most severe level
105 16 amber intake manifold 1
temperature
data valid but above normal operating
range, moderately severe level
108 3 amber barometric pressure sensor voltage above normal or shorted to high
source
108 4 amber barometric pressure sensor voltage below normal or shorted to low
source
108 2 amber barometric pressure sensor data erratic, intermittent, or incorrect
110 3 amber engine coolant temperature 1
sensor
voltage above normal or shorted to high
source
110 4 amber engine coolant temperature 1
sensor
voltage below normal or shorted to low
source
110 16 amber engine coolant temperature data valid but above normal operating
range, moderately severe level
110 0 red engine coolant temperature data valid but above normal operational
range, most severe level
110 31 amber engine coolant temperature condition exists
111 3 amber coolant level sensor 1 voltage above normal or shorted to high
source
SPN FMI Warning
Color