Electric Strike System
CMW
Use Electric Strike Simulator
Use the Electric Strike Simulator (p/n 259-506) to test voltage and current sensors on ESID. If readings are
less than indicated here, replace 9V battery in simulator and retest.
Current Test
To test for current at normal levels:
1. Thread one lead wire through current transformer.
2. Clip ends of lead wires together to make one loop.
3. Select Module, ESID menu on Information Center.
4. Move simulator switch to "current" and press test button.
5. Watch display on Information Center.
ESID bar graph should show 1/2 scale on display.
ESID % and Current "AMPS" should show 30-50% in display.
To test for current at strike levels:
1. Put two or three loops through current transformer.
2. Follow steps above to test.
3. Display should show the following:
ESID bar graph should show full bar.
Alarm and strobe should turn on.
ESID and STK LED should flash.
With two loops,
Current "Amps" should be 80-110%.
Strike indication might go on and off.
With three loops,
Current should be 130-160%.