Pipeloader
CMW
Add/Remove Single Pipe
Load a drill pipe into an empty column of pipe box to finish bore without changing pipe boxes.
Electric shock. Contacting electric lines will cause death or serious injury.
Know location of lines and stay away.
To help avoid injury: Do not attempt to load and unload pipe while drilling or backreaming. Load or
unload all of the pipes that will be needed before resuming drilling or backreaming. Unprotected worker
can be injured by electric strike.
NOTICE:
Open or close both auxiliary pipe loaders. Moving shuttles with one auxiliary pipe loader open and
one closed will damage equipment and cause possible injury.
Carriage must be all the way back on the rear stop switch to load and unload pipe.
Use caution when loading single pipes on side slopes.