Manual

JT30 /JT30 All Terrain Operator’s Manual Systems and Equipment - 184
Diagnostic Codes
CMW
441 ICTR PHYS ERR errors on CMW CAN Bus
totalling 275 have been
logged
throttle, engine fan, and
some status lights no longer
work correctly; may recover
if condition clears
non-
essential
442 1939 PHYS ERR errors on the J1939 Bus
totalling 275 have been
logged
443 ICTR BUS OFF Information Center has shut
down CMW CAN
communications
444 1939 BUS OFF Information Center has shut
down J1939
communications
445 ICTR PROTOCOL Information Center has an
incorrect CMW CAN
protocol message
code is stored in Information
Center
446 1939 PROTOCOL Information Center has an
incorrect J1939 protocol
message
code is stored in Information
Center
447 ICTR NG FAIL Information Center has
detected a CAN nodeguard
timeout
code is stored in Information
Center
448 1939 NG FAIL Information Center has
detected a J1939 nodeguard
timeout
code is stored in Information
Center
449 ICTR LOG FAIL Information Center has had
an internal CMW CAN
software failure
throttle, engine fan, and
some status lights no longer
work correctly
450 1939 LOG FAIL Information Center has had
an internal J1939 software
failure
throttle, engine fan, and
some status lights may not
work correctly
non-
essential
452 MAIN MSG TOUT CAN message from main
controller failed to arrive
code is shown and display
waits for next message
non-
essential
453 PIPE MSG TOUT CAN message from
pipeloader controller failed
to arrive at info center
code is shown and display
waits for next message
non-
essential
454 ESID MSG TOUT CAN message from ESID
failed to arrive at info center
code is shown and display
waits for next message
non-
essential
455 OPER MSG TOUT operations CAN message
failed to arrive at info center
code is shown and display
waits for next message
non-
essential
Code Display Condition Result Severity