Welder User Manual

Service - 84 PR95 Operator’s Manual
As Needed
CMW
Power Unit
Change Air Filter
Change air filter as needed.
To change
1. Disengage clasps (2) and remove end cup.
2. Remove primary element (3).
3. Remove secondary element (4), if dirty.
4. Wipe inside of housing and wash end cup.
5. Install new element(s).
6. Install end cup and engage clasps.
7. Reset air filter service indicator (1).
Adjust Fan Belt Tension
1. Turn off engine and remove key.
2. Apply moderate thumb pressure to belt
between pulleys, as shown.
3. Belt is properly tensioned when deflection is
about 1/4-3/8” (7-9 mm).
4. If needed, loosen alternator bolts (shown) and
pull alternator out until correct tension is
reached.
5. Tighten alternator bolts.