Instruction Manual

SK850 Operator’s Manual Transport - 59
Tow
CMW
®
Tow
Under normal conditions, unit should not be towed. If unit breaks down and towing is necessary:
attach chains to tow points facing towing vehicle
tow for short distances at less than 1 mph (1.6 km/h)
do not tow for more than 100’ (30 m)
use no more than 1,300 lb (5800 N) of towing force
open bypass valve on each pump section
if engine will not start, remove rear panel and unbolt parking brake assembly
Read operator’s manual. Know how to use all controls.
Your safety is at stake.
273-475
NOTICE: When bypass valve is open, unit has no brakes.
t43om010w.eps
rear tow point front tow point