Fryer User Manual
SUPER RUNNER SERIES GAS FRYERS 
CHAPTER 1: INSTALLATION INSTRUCTIONS 
1-2 
For units equipped with legs: Lift the unit and move it into its final position. Do not drag or push the fryer into position. 
Doing so may damage the legs. Level the unit front to back and side to side. If the fryer is not level, the unit will not 
function efficiently. Super Runner Series gas fryers cannot be curb mounted
 and must be equipped with either legs or 
casters provided. 
A.  Adjust leg height with an adjustable or 1-1/16-inch (27-mm) open-end wrench by turning the hexagon-shaped foot 
on the bottom of the leg. NOTE: The foot is for minor leg height adjustment only. Do not adjust outward more 
than ¾-inch (19-mm). 
B.  When leveling the unit, the leg body should be held firmly to keep the leg from bending or rotating while turning the 
foot to the required height. 
For units equipped with casters: Roll the unit into its final position and lock the front casters. 
1.3 Pre-Connection Preparation 
 WARNING 
If the incoming gas pressure is in excess of ½" PSI (3.45 kPa/35 mbar), a step-down regulator will be 
required. 
CE UNITS ONLY: 
Dean Super Runner gas fryers have obtained CE markings for countries and gas categories shown below: 
Countries  Supply Pressures and Gas (mbar)  Appliance Categories 
G20  20/25 
BE Belgium 
G31  37 
IIE(R)B3P 
G20  20  I2E 
DE Germany 
G31 50  I3P 
DK Denmark  G20  20  I2H 
G20 20 
ES Spain 
G31  37 and 50 
II2H3P 
G20/G25 20/25 
FR France 
G31  37 and 50 
II2ESI3P 
G20 20 
GB Great Britain 
G31 37 
II2H3P 
G20 20 
GR Greece 
G31  37 and 50 
II2H3P 
G20 20 
IR Ireland 
G31 37 
II2H3P 
IT Italy  G20  20  I2H 
G20/G25 20/25 
LU Luxembourg 
G31 50 
II2E3P 
G25 25 
NL The Netherlands 
G31 50 
II2L3P 
G20 20 
PT Portugal 
G31 37 
II2H3P 
NON-CE UNITS ONLY: 
NATIONAL CODE REQUIREMENTS: 
This equipment is to be installed in compliance with the Basic Plumbing Code of the Building Officials and Code 
Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the U.S. Food and Drug 
Administration. 
This equipment is manufactured to use the type of gas specified on the rating plate attached to the door. Connect 
equipment stamped "NAT" only to natural gas and that stamped "PRO" only to LP (Propane) gas. 