Fryer User Manual
SUPER RUNNER SERIES GAS FRYERS 
CHAPTER 2: OPERATION 
2-3 
 DANGER 
"Dry-firing" the fryer will cause damage to the frypot and can cause a fire. Always ensure that shortening, 
cooking oil or water covers the burner tubes before lighting the burners. 
2.  With the pilot lit, push down and slowly turn the gas valve knob to the ON position. 
3.  Rotate the operating thermostat knob to the desired frying temperature. The burner should light and burn with a 
strong blue flame. 
 DANGER 
If the pilot and burners go out, the fryer must be completely shut down at least five minutes before re-
lighting. 
2.2 Shutting the Fryer Down 
For temporary shutdown, turn the operating thermostat to the OFF position and cover the frypot. 
For complete shutdown, turn the operating thermostat to the OFF position, turn the gas valve knob to the OFF position 
(Non-CE) or press the red button (CE) and cover the frypot. 
2.3 Daily Operation 
1.  Do not allow grease to accumulate or harden on the frame, body, or flue of the fryer. Clean the fryer inside and out 
with a solution of detergent and hot water daily. 
2.  Filter the cooking oil by draining the frypot through a filter cone at least daily. After the oil has been drained from 
the frypot, remove any residue from the pot, using a scraper if necessary. 
3.  Clean the frypot at least once each week by filling it to just below the upper oil level mark with water. Add one cup 
of detergent and bring the solution to a boil. Allow the solution to simmer for 10-15 minutes, then drain and rinse 
the frypot with clean water twice. Add ΒΌ cup of white vinegar to the last rinse to neutralize any alkalinity remaining 
from the detergent. Wipe the frypot surfaces with a dry towel before refilling with cooking oil. If the fryer is not to 
be used immediately after cleaning, it is suggested that the inside of the frypot be wiped down with a light coat of 
cooking oil to prevent rust. 
2.4 Recommended Spare Parts 
DESCRIPTION 
PART # 
SR42- NON-
CE 
PART # 
SR42- CE 
PART # 
SR52/SR62- NON-CE 
PART # 
SR52/SR62- CE 
Operating Thermostat  807-3515  807-1692  807-3515  807-1692 
High-Limit Thermostat  807-3516  807-3560  807-3680  807-3560 
Thermopile 810-2033 807-3565 810-2033 807-3565 
Thermocouple N/A 812-1284 N/A 812-1284 
Pilot Burner, Natural Gas  810-2032  810-2032  810-2032  810-2032 
Pilot Burner, Propane Gas  810-2155  810-2155  810-2155  810-2155 
Pilot Bracket, AGA  N/A  200-6564  N/A  200-6564 
Pilot Thermopile Bracket  N/A  810-2401  N/A  810-2401 
Piezo Ignitor Trigger  N/A  810-1001  N/A  810-1001 
Piezo Ignitor Bracket  N/A  200-1868  N/A  200-1868 
Piezo Ignitor Electrode  N/A  807-3540  N/A  807-3540 
Orifice, Natural  810-2040  810-2060  810-2048  810-2060 
Orifice, Natural, units built after 4/07  810-3097  810-3101  N/A  N/A 
Orifice, Propane  810-2064  810-2059  810-2059  810-2059 
Orifice, Propane, units built after 4/07  810-3099  810-3102  N/A  N/A 
Gas Valve, Natural  807-1603  807-2122  807-1603  807-2122 
Gas Valve, Propane  807-1604  807-2121  807-1604  807-2121 
Leg 810-2053 810-2053 810-2053 810-2053 
Caster, 5-inch w/o Brake  810-0356  810-0356  810-0356  810-0356 
Caster, 5-inch w/Brake  810-0357  810-0357  810-0357  810-0357 