Fryer User Manual
SUPER RUNNER SERIES GAS FRYERS 
CHAPTER 1: INSTALLATION INSTRUCTIONS 
1-3 
AUSTRALIAN REQUIREMENTS: 
To be installed on a firm, level surface in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any 
other relevant statutory regulations. The Australian orifice size and manifold pressures are listed below for the SR62. 
Model  Gas Type  Orifice Size  Manifold Pressure KPa  Manifold Pressure Inches WC 
SR62  Nat  2.53 mm  0.9 KPa  3.6” 
SR62  Prop  1.6 mm  2.4 KPa  9.6” 
CE UNITS ONLY: 
Nominal Heat Inputs (Qn), Gas Type, Orifice Size, Pressures and Adjustments, Orifice Quantity/Color, Burner Markings 
and Pilot Markings are listed in the table below: 
MANIFOLD GAS PRESSURE 
MODEL* 
NOMINAL 
HEAT INPUT- 
Qn 
(kW) 
GAS TYPE 
ORIFICE 
SIZE (MM) 
MBAR INCH W.C. 
ORIFICE 
QTY/ COLOR 
BURNER 
MARKING
PILOT 
MARKING 
SR62 GM  37.5 
G20 
G25 
G31 
2.40 
2.40 
1.51 
12,0 
17,5 
22,0 
4,8 
7,0 
8,8 
5/BLUE 
5/BLUE 
5/RED 
Blue 
Blue 
Red 
26N 
26N 
16LP 
SR52 GM  30 
G20 
G25 
G31 
2.40 
2.40 
1.51 
12,0 
17,5 
22,0 
4,8 
7,0 
8,8 
4/BLUE 
4/BLUE 
4/RED 
Blue 
Blue 
Red 
26N 
26N 
16LP 
SR42 GM  26 
G20 
G25 
G31 
2.40 
2.40 
1.51 
12,0 
17,5 
22,0 
4,8 
7,0 
8,8 
3/BLUE 
3/BLUE 
3/RED 
Blue 
Blue 
Red 
26N 
26N 
16LP 
*SR prefix- Super Runner Series               
*GM suffix- gas millivolt system with no electrical supply connections required  
NON-CE UNITS ONLY: 
Nominal Heat Inputs (Qn), Gas Type, Orifice Size, Pressures and Adjustments, Orifice Quantity, and Pilot Markings are 
listed in the table below: 
MODEL* 
NOMINAL 
HEAT INPUT- 
Qn 
(BTU) 
GAS TYPE
ORIFICE 
SIZE (MM) 
MANIFOLD GAS 
PRESSURE 
(INCH W.C.) 
ORIFICE 
QUANTITY 
PILOT 
MARKING 
SR62 GM  150 
NAT 
LP 
2.53(#39) 
1.51(#53) 
4 
11 
5 
5 
26N 
16LP 
SR52 GM  120 
NAT 
LP 
2.53(#39) 
1.51(#53) 
4 
11 
4 
4 
26N 
16LP 
SR42 GM  105 
NAT 
LP 
2.80(#35) 
1.70(#51) 
4 
11 
3 
3 
26N 
16LP 
*SR prefix- Super Runner Series             
*GM suffix- gas millivolt system with no electrical supply connections required       
NOTE:
 Outlet gas pressure must be adjusted strictly within the above requirements 5 to 10 minutes after the appliance is 
operating. 
1.4  Connection to the Gas Supply Line 
NOTE: The gas supply (service) line must be the same size or greater 
than the fryer inlet line. This appliance is equipped with a ½-inch (15-
mm) inlet. The gas supply line must be sized to accommodate all gas-
fired equipment connected to the line. Consult the local gas company 
or supplier, or your local contractor for minimum supply line 
requirements. 
NOTE: If quick-disconnect supply lines or flex lines are used, 
increase supply line size to ¾-inch (22-mm) or larger. 
Propane Applications; 
Proper Regulator Must Be Installed 