User guide
Using the NiTek X
NiTek X Dive Computer User Manual v1.1 40
Oxygen-analysis mode, screen 3
(5) and (6): mV reading and O2 percentage: This shows that
the oxygen-cell has been calibrated and is displaying its output.
To enter the OXY mode:
1. Using the Battery Door Tool, remove the knurled cap at
upper left of NiTek X and attach the appropriate external
cable and oxygen-cell to the connector. Be sure to hold the
computer with its left side facing down to minimize any
water droplets from getting into the compartment.
2. Repeatedly press button A until “OXY” is displayed.
3. Press button B to enter the OXY analysis mode screen.
“0 mV Uncalibrated” is displayed on the screen.
4. Press button A
“CAL O2” is displayed on the screen.
5. Press button B to enter calibrate-mode of oxygen-cell, using
a source of 100% oxygen for reference.
“xx mV calibrated” (where xx is the mV reading of your
oxygen-cell) and the oxygen percentage is displayed on the
screen.
6. To return to surface mode, press and hold button A for 2 to 3
seconds.
7. Set the NiTek X to “C/C” (closed-circuit) mode. It will
display “EXT” instead of “SP” (setpoint), indicating that it is
reading the PO2 level of the external oxygen-cell.
5
6