Condensate Pump Installation and Safety Instructions
CP-22 CP-22LP CP-22T CP-22LPT CP-22-230 CP-22LP-230 CP-22T-230 CP-22LPT-230 Rated Voltage 120 Volts / 60 Hz 220 Volts / 60 Hz (208-230) Rated Current Draw 1.9 Amps 1.0 Amps Input Type USA 3-prong plug NEMA 6-15 plug Head Height 22 ft. maximum 22 ft. maximum Flow Rate at Zero Head 1.6 GPM 1.6 GPM Product Dimensions (LxWxH) 11.8” x 5.9“ x 6.7” (4.9“H low profile) 11.8” x 5.9“ x 6.7” (4.9“H low profile) Product Weight 5 lbs. (4.7 lbs. low profile) 5 lbs. (4.7 lbs.
Limited Warranty All pumps manufactured by or for DiversiTech Corporation (the Company) and sold by the Company under the DiversiTech brand are warranted to be free of defects in workmanship and materials for a period of 24 months from date of sale from the distributor to the contractor. The Company will credit, repair or replace, at its option, any Pump if deemed defective within this time period. All products returned to the Company must include a return authorization issued by the Company.
General Information Thank you for the purchase of this DiversiTech condensate pump. This pump is designed to automatically remove the condensate water that collects from appliances such as air conditioners, high-efficiency furnaces and de-humidifiers. The pump has a built-in tank that collects the water from the appliance. When the water collected reaches sufficient level inside the pump tank, the pump switches on and pumps the water to a remote location for disposal.
Mounting The condensate pump is equipped with metal mounting tabs which allow the tank to be screwed to a wall or equipment side panel. The screw-to-screw distance is 8”. When mounting into drywall or concrete walls the screws must have anchors which provide the necessary support in the wall material. The pump top is reversible. It may be turned around to allow easy access to the pump outlet, pan tab tray or power connection as may be required by the particular installation.
All aspects of the installation must conform to requirements of the NEC, and any applicable local codes. Safety Switch The pump safety switch should be used on 24V Class II control circuits only. The pump safety switch connections are available on standard ¼” quick connect terminals located on the top cover. Two wires with pre-crimped connectors may be plugged onto the COMMON and RUN terminals and wired into the 24 Volt thermostat circuit to shut off A/C systems should an overflow condition occur.