Condensate Pumps Specifications

Specications
ClearVue
Pump
TECHNICAL DATA SHEET
www.diversitech.com
1.800.995.2222
ClearVue™ Pump
High eciency condensing furnaces and humidiers
This product is designed to automatically pump condensate
produced by high eciency condensing furnaces and humidiers
to any height up to 22’ vertically once the level of condensate in
the tank reaches a specied level.
With DiversiTech’s Floatless Sensor™ technology, ClearVue™
eliminates the oat switch - one of the most common problems
with conventional condensate pumps. ClearVue™ uses patent
pending water sensing technology to detect condensate so that
there are no more stuck oats. ClearVue™ also features a
see-through tank to give the service tech and homeowner a clear
view of water, blockage, and buildup in the tank. This clear tank
allows for quick and easy troubleshooting.
iQ Technology™:
Variable Li: The variable li in ClearVue™ assures that the
pump impeller is spinning only as fast as is needed to li the
condensate water to the height needed.
Self Cleaning: By monitoring pumping conditions, ClearVue™ is
able to detect when a drain line is partially or fully clogged. In
these instances, ClearVue™ increases the pressure in the drain
line to attempt to clear the clog.
Floatless Sensor™: DiversiTech’s patent pending Floatless Sensor™
eliminates many of the mechanical problems associated with
conventional condensate pumps.
• Continuous duty 140F°
• Maximum inlet temperature 160F°
• Not suitable for contact with steam or gasses that exceed 160F°
120 VAC / 230VAC / 60Hz
• 1.9 Amps (120VAC)
• 1.0 Amps (230VAC)
• USA 3-prong molded plug (120VAC)
• NEMA 6-15 plug (230VAC)
Variable, 0 to 22 feet
1.6 gallons per minute
• 11.8” x 5.9“ x 6.7”
• 5 lbs.
4.4”
1/2 gallon
• Instruction Sheet
• Stainless Steel Hang Tabs
• Plug Protector
• 4’ Remote Shuto Leads w/insulated terminals
• Polyethelene inlet covers (3)
• 120V
Black - Live/Hot
White - Neutral
Green - Ground
(All installations must conform to NEC requirements)
• 230V
Brown - Live/Hot
Blue - Neutral
Green/Yellow - Ground
(All installations must conform
to NEC requirements)
Product
Application
Purpose
Advantages
Maximum Condensate
Temperatures
Rated Voltage
Rated Current Draw
Input Type
Maximum Li Height
Flow Rate @ Zero Head
Dimensions
Inlet Height from Base
Tank Capacity
Included Accessories
Wiring Color
References