ClearVue Pump ™ System Installation PUMP ™
Contents Introduction 3 Variable Speed and Lift 5 Floatless Sensor™ 7 Other Features System Installation 9 10 11 12 Unpacking, Pump Location and Mounting Electrical and High Level Alarm Connection Inlet and Outlet Tubing Connections Electrical Installation Requirements and Safety Switch Connections Operation 12 Power, Pump Test, and Normal Operation 13 Variable Lift, Cleaning, and Homeowner Instruction Reference and Troubleshooting 14 Button Reference Chart 15 LED Indicator Reference Chart Technical
Introducing…..ClearVue™ Thank you for the purchase of the ClearVue™ condensate pump. ClearVue™ automatically removes condensate water just like a standard condensate pump but with many customer inspired improvements. Variable Speed and Lift - See page 3 and 4. Floatless Sensor™ - See page 5. ™ With DiversiTech’s Floatless Sensor™ technology, ClearVue™ eliminates the float switch - one of the most common problems with conventional condensate pumps.
Variable Speed and Lift ClearVue™ pump’s floatless sensor technology senses how fast water is filling the tank and determines how hard the ClearVue™ needs to pump in a given installation, then pumps only to that height. If there is a partial clog in the drain line, ClearVue™ figures that out, and pumps a little harder. If the clog doesn’t clear, ClearVue™ goes into a cleaning cycle and pulses the discharge water to try to dislodge the clog.
™
CHECK FOR SHIPMENT DAMAGE
Variable Lift ClearVue™ pump features variable speed and lift. ClearVue™ pumps only as hard as it needs to, in a given installation, to lift the condensate water away. The lower the lift, the slower the pump runs, and the quieter the operation.
Button Function Manually test motor operation Manually drain water from pump Run a clean cycle Activate or deactivate the audible alarm Silence the audible alarm (when enabled)
LED Indicator Light Status Solid Green LED Solid Amber LED Solid Amber LED & Flashing Red LED Solid Amber LED & Flashing Red LED & Flashing White LED Flashing White LED Flashing White LED & Solid Amber LED Flashing Blue LED Indicates that pump sensors are operational.
Symptom Possible Condition
Corrective Action
120 Volt version Rated Voltage 120 Volts / 60 Hz Rated Current Draw 1.9 Amps Input Type USA 3-prong plug Head Height 22 ft. maximum Flow Rate at Zero Head 1.6 GPM Maximum Rated Inlet Flow Rate 500mL/min Temperature Rating • Continuous duty 140F˚ • Max inlet temperature 160F˚ • Not suitable for contact with steam or gasses that exceed 160F˚ Product Dimensions 11.8” x 5.9“ x 6.7” Product Weight 5 lbs. Inlet Height from Base 4.
About DiversiTech 6650 Sugarloaf Parkway Duluth, GA 30097 678.542.3600 800.995.2222 678.542.3700 Fax DiversiTech Corporation is North America’s largest manufacturer of equipment pads and a leading manufacturer and supplier of components and related products for the heating, ventilating, air conditioning, and refrigeration (HVACR) industry.