Install Instructions

www.diversitech.com
1.800.995.2222
ASSEMBLY INSTRUCTIONS
Pitched Roof Mini-Split
maximun spread load
310 lbs 140 Kg
Disclaimer: this document cancels and replaces all former versions. We reserve us the right to amend it without prior notice. It is the sole and entire responsibility of the customer to obtain the
most recent version in force of this document. It can be obtained by a simple written request to the Seller. The products mentioned in this document are exclusively for *HVAC-R professionals
customers ( *Heating, Ventilation, Air Conditioning and Refrigeration). This product is a wall bracket designed for the support of an external condensing split air conditioner device. Neither Seller
nor the Manufacturer shall be liable for any injury, loss or damages, either direct, incidental or consequential (including, but not limited to, incidental or consequential damages for lost prots, lost
sales, injury to person or property, or any other incidental or consequential loss) arising out of the use or the inability to use the product, and the customer agrees that no other remedy shall be
available to it. The customer is required to control whether the products mentioned in this document are appropriate for their intended use.
As totally beyond the control of the Manufacturer and the Seller, it is the sole and entire responsibility of the customer to check and comply with all national, state, local and environmental re-
gulations, safety factors according to intended application. It is also the customer's sole and entire responsibility to choose and use appropriate tools and materials according to the professional
know-how, in conformity to the installation and maintenance instructions as well as recommendations in the manuals of the air conditioning device. It is as well the customer's sole and entire
responsibility to evaluate if the supporting structure and elements, composition and surface, and if the supplied xations are suitable for a safe and professional installation on the type of wall
structure or surface that will be used to install the brackets and the air conditioning device on taking into account climatic conditions in use and during the installation. At least once per year the
inspection of the tightening of the xations as well as of the general condition of the bracket is required.
All claims or disputes are subject to the Manufacturer's and the Seller's General Conditions of Sales.
1 2
5 6
3 4
FS631
VTE M8x40
UNI 5739
4 PCS
8x24
4 PCS
Ø 40
4 PCS
Ø 25
4 PCS
M8 UNI 5588
BRACKERS 4 PCS
M6X55 2 PCS
M8x80
4 PCS
M8 UNI 5692 4 PCS
RG632
VTE M8x20 4 PCS
M6 UNI 5588 4 PCS
M6X65 2 PCS
LEVEL 1 PCS
AV 210
A
F
E
D
C
B
M8 UNI 6592
4
PCS
4 PCS
VTE M8x40
UNI 5739
4 PCS
8x24
4 PCS
Ø 40
4 PCS
Ø 25
4 PCS
M8 UNI 6592
4 PCS
M8 UNI 5588
4 PCS
M6X55
2 PCS
BRACKERS
4 PCS
VTE M8x20
4 PCS
M6 UNI
5588 4 PCS
M6X65
2 PCS
LEVEL
1 PCS
RG 632
M
N
H
G
L
I
AV210
VTE M8x40
UNI 5739
4 PCS
8x24
4 PCS
Ø 40
4 PCS
Ø 25
4 PCS
M8 UNI 6592
4 PCS
M8 UNI 5588
4 PCS
BRACKERS 4 PCS
M6X55 2 PCS
M8x80
PCS
M8 UNI 5692
6 PCS
RG632
VTE M8x20 4 PCS
M6 UNI 5588 4 PCS
M6X65 2 PCS
LEVEL 1 PCS
FS 631
O
D
6
by

Summary of content (1 pages)