Matrice 30 Series - User Manual
Table Of Contents
- Using This Manual
- Product Profile
- Flight Safety
- Aircraft
- Remote Controller
- Starting and Activating the Remote Controller
- Remote Controller Overview
- Mounting the WB37 Intelligent Battery
- Mounting the Dongle
- Mounting the Strap and Bracket Kit
- Adjusting the Antennas
- IP Rating
- User Interface
- Video Transmission
- Remote Controller LEDs and Alert
- Charging the Remote Controller and Checking the Battery Level
- Linking the Remote Controller and Control Stick Modes
- Buttons Overview
- Flight Mode Switch (N/S/F)
- Calibrating the Compass
- HDMI Settings
- Advanced Dual Operator Mode
- Intelligent Battery Station
- Intelligent Flight Battery
- DJI Pilot 2 App
- Firmware Update
- Appendix
125
©
2022 DJI All Rights Reserved.
MATRICE 30 SERIES User Manual
Bluetooth
Protocol Bluetooth 5.1
Operating Frequency 2.4000-2.4835 GHz
Transmitter Power (EIRP) <10 dBm
Intelligent Battery Station
Model CSX320-550
Dimensions 353×267×148 mm
Net Weight 3.95 kg
Compatible Battery Type
TB30 Intelligent Flight Battery
WB37 Intelligent Battery
Input 100-240 VAC, 50/60 Hz
Output
TB30 Battery Port: 26.1 V, 8.9 A (supported up to two outputs
simultaneously)
WB37 Battery Port: 8.7 V, 6 A
Output Power 525 W
USB-C Port Max. output power of 65 W
USB-A Port Max. output power of 10 W (5 V, 2 A)
Power Consumption
(when not charging battery)
< 8 W
Output Power
(when warming up battery)
Approx. 30 W
Operating Temperature -20° to 40° C (-4° to 104° F)
Ingress Protection Rating IP55 (with the cover closed properly)
Charging Time
[6]
Approx. 30 min (charging two TB30 batteries from 20% to 90%)
Approx. 50 min (charging two TB30 batteries from 0% to 100%)
Protection Features
Anti-Backow Protection
Short Circuit Protection
Over Voltage Protection
Over Current Protection
Temperature Protection
[1] 5.8 and 5.1GHz frequencies are prohibited in some countries. In some countries, the 5.1GHz frequency is
only allowed for use indoors.
[2] The maximum ight time and the hover time were tested in a lab environment and is for reference only.
[3] This protection rating is not permanent and may reduce over time after long-term use.
[4] The infrared temperature measurement accuracy was tested in a lab environment and is for reference only.
[5] The maximum operating time was tested in a lab environment and is for reference only.
[6] The charging time was tested in a lab environment at room temperature. The value provided should be
used for reference only.