Operation Manual

©
2016 DJI All Rights Reserved.
19
MATRICE 600
User Manual
1. Connect the battery charger to a suitable power supply (100-240V 50/60Hz).
2. Open the protection cap and connect the Intelligent Flight Battery to the battery charger. If the
battery level is above 95%, turn on the battery before charging.
3. The Battery Level Indicator will display the current battery level during charging.
4. The Intelligent Flight Battery is fully charged when Battery Level Indicators are all off. Disconnect
the Intelligent Flight Battery from the battery charger.
DO NOT charge the Intelligent Flight Battery and the remote controller at the same time to
avoid overloading the battery charger (model: A14-100P1A).
Air cool the Intelligent Flight Battery after each ight. Allow its temperature to drop to room
temperature before charging.
The charging temperature range is to 40° C. The battery management system will stop
the battery from charging when the battery cell temperature is out of range.
Charger
Intelligent Flight Battery
Power Outlet
Battery Level Indicator While Charging
LED1 LED2 LED3 LED4 Battery Level
0%~25%
25%~50%
50%~75%
75%~100%
Fully charged
Charging Protection LED Display
The table below describes the battery protection mechanisms and their corresponding LED patterns.
Battery Level Indicator While Charging
LED1 LED2 LED3 LED4 Indicator Pattern Battery Protection Item
LED2 blinks twice per second Overcurrent detected
LED2 blinks three times per second Short circuit detected
LED3 blinks twice per second Overcharge detected
LED3 blinks three times per second Charger overvoltage detected
LED4 blinks twice per second
Charging temperature is too
low (<5°C)
LED4 blinks three times per second
Charging temperature is too
high (>40°C)