Operating instructions

TransTel TD-1648i / TDS-600 Programming Manual
103
Form 35 - CO Line Specifications #2
Data 01 02 03 04 05 06 07 08
Range 0-1 0-1 0-8 0-3 0-1 0-1 0-9 0-9
Default 0 1 0 0 3 0 0 0
Item Valid
Settings
Description
Settings
Default
35-tk-01 0-1 Trunk Type 0=CO
35-tk-02 0-1 Dialing Signal 1=DTMF
35-tk-03 0-8 External Call Forward 0=No
35-tk-04 0-8 DISA 0=No
35-tk-05 0-3 Pick Up 3=Yes
35-tk-06 0-1 Loud Bell 0=No
35-tk-07 0-5 Inward Line Ringing Type - Day 0=Com
35-tk-08 0-5 Inward Line Ringing Type - Night 0=Com
35-
XX
-01
-
L
INE
T
YPE
:
0=CO Line (Connected to Telco Lines) 1=Behind PABX (Connected to a PABX Extension or
Centrex line)
35-
XX
-02
-
D
IAL
S
IGNALING
T
YPE
:
0=Pulse Dialing 1=DTMF Dialing
35-
XX
-03
-
E
XTERNAL
C
ALL
F
ORWARDING
L
OCATION
:
(Only applicable if 35-CO-04 is programmed for External Call Forwarding)
0=Not Active 1=Speed Dial 101 2=Speed Dial 102 3=Speed Dial 103
4=Speed Dial 104 5=Speed Dial 105 6=Speed Dial 106 7=Speed Dial 107
8=Speed Dial 108
35-
XX
-04
-
DISA
/
E
XTERNAL
C
ALL
F
ORWARD
S
TATUS
:
0=Day Disable/Night Disable
1=Day Disable/Night DISA 2=Day DISA/Night Disable
3=Day DISA/Night DISA 4=Day Disable/Night ECF
5=Day ECF/Night Disable 6=Day ECF/Night ECF
7=Day DISA/Night ECF 8=Day ECF/Night DISA