Operating instructions
TransTel TD-1648i / TDS-600 Programming Manual 
103
Form 35 - CO Line Specifications #2 
Data   01  02  03  04  05  06  07  08 
Range  0-1  0-1  0-8  0-3  0-1  0-1  0-9  0-9 
Default  0  1  0  0  3  0  0  0 
Item  Valid 
Settings 
Description   
Settings 
Default 
35-tk-01  0-1  Trunk Type    0=CO 
35-tk-02  0-1  Dialing Signal    1=DTMF 
35-tk-03  0-8  External Call Forward    0=No 
35-tk-04  0-8  DISA    0=No 
35-tk-05  0-3  Pick Up    3=Yes 
35-tk-06  0-1  Loud Bell    0=No 
35-tk-07  0-5  Inward Line Ringing Type - Day    0=Com 
35-tk-08  0-5  Inward Line Ringing Type - Night    0=Com 
35-
XX
-01
-
L
INE 
T
YPE
: 
0=CO Line (Connected to Telco Lines)  1=Behind PABX (Connected to a PABX Extension or 
Centrex line) 
35-
XX
-02
-
D
IAL 
S
IGNALING 
T
YPE
: 
0=Pulse Dialing  1=DTMF Dialing 
35-
XX
-03
-
E
XTERNAL 
C
ALL 
F
ORWARDING 
L
OCATION
:
(Only applicable if 35-CO-04 is programmed for External Call Forwarding) 
0=Not Active  1=Speed Dial 101  2=Speed Dial 102  3=Speed Dial 103 
4=Speed Dial 104  5=Speed Dial 105  6=Speed Dial 106  7=Speed Dial 107 
8=Speed Dial 108   
35-
XX
-04
-
DISA
/
E
XTERNAL 
C
ALL 
F
ORWARD 
S
TATUS
: 
0=Day Disable/Night Disable 
1=Day Disable/Night DISA  2=Day DISA/Night Disable 
3=Day DISA/Night DISA  4=Day Disable/Night ECF 
5=Day ECF/Night Disable  6=Day ECF/Night ECF 
7=Day DISA/Night ECF  8=Day ECF/Night DISA 