Descriptio
n:
The G2-
MSC
provides 1
Sensor.
Each
Sensor can
be assigned one of the following 18 functions in items 39-01in the TD-1648i/TDS-600 .
00 No Operation 03 Door Phone 1 ( 88 )
01 Fire Alarm 04 – 18 Reserved for future use
02 Break Alarm
The SENSOR type may be normally open or normally closed and can be set to be activated in Day or Night
switching or in both. Parameters 39-02 in the TD-1648i/TDS-600 set each sensor contact to be a normally open
or normally closed type and set whether to work in Day or Night Mode or both.
0 = Disable Sensor function 4 = Normally Closed, Activated for Nighttime.
1 = Normally Open, Activated for Daytime. 5 = Normally Open, Activated for Day and Nighttime
2 = Normally Closed, Activated for Daytime. 6 = Normally Closed, Activated for Day and Nighttime.
3 = Normally Open, Activated for Nighttime.
The applications are as follows:
1 = Fire Alarm: Sensor detects fire, all idle extensions will be rung and all busy extensions will
Hear the alarm tone. The fire alarm will continue for 10 minutes.
Dialing [7][7][7] from the console will stop the fire alarm.
The LCD display will show FIRE ALARM !!!! when the alarm is activated.
2 = Break Alarm
The Sensor detects the signal appears, all idle extensions will be rung.
The Sensor detects the signal disappears, all extensions will stop ringing.
The LCD display will show BREAK ALARM !!!! when the alarm is activated.
Individual stations can be programmed to not receive the Break Alarm in Form 45-st-06.
The ring cadence for the fire alarm will be as follows
A B c b A b C b a b
a = 1.25 seconds On b = 0.25 seconds off c = 0.25 seconds on.
If door key has been set in Form 07 and Form 39, the Door key on DSS will get the following indications:
LED Indication Door Phone Status
Off Normal Close for Sensor
Red-Slow Flashing Normal Open for Sensor
Red-Fast Flashing Door Phone Is Calling
Green on This Station is talking to Door Phone
Red on Some other Station is talking to Door Phone
Form 39-000-IP - Sensor Assignments
Form 39-Item- 01 02 Name - (Reference Only – Not
programmed in system)
Form 39-