Form 40 - Station Class of Service (Part 1)
Item
Valid
Settings
Description
Default
40-st-01 0-9,d Override/OHCA Level 1=Low
40-st-02 0-9 Monitor Level 1=Low
40-st-03 0-9 Limit Call Duration 0=No
40-st-04 0-1 Station Loud Bell 0=No
40-st-05 0-1 Access Paging 0=Yes
40-st-06 0-1 Receive Paging 0=Yes
40-st-07 0-1 Security Code Status 0=None
40-st-08 00-48 Forced Account Code 00=All
General:
This programming Mode permits each station to be assigned a different Class of Service.
Description:
40-
EXT
-01
-
O
VERRIDE AND
OHCA
L
EVEL
:
Higher level stations can override lower level stations, equal levels may override each other.
0=Unable to Override/Disable OHCA 1-9=Can Override equal and lower numbered levels
40-
EXT
-02
-
M
ONITOR
L
EVEL
:
Higher level stations can monitor lower level stations, equal levels can not monitor each other.
0=Unable to Monitor 1-9=Can Monitor lower numbered levels
40-
EXT
-03
-
C
ALL
L
IMIT
D
URATION
:
Conversation will be interrupted by a BusyTone. A warning tone will be given 10 seconds before the end of
the timed duration. (see form 05-04-03 to set call limiting action)
Related System Programming Mode: 05-04-03, 40-st-03
0=No Duration Limit 1=3 minutes 2 = 5 minutes
3 = 10 min 4 = 15 minutes 5 = 20 minutes
6 = 30 minutes 7 = 40 minutes 8 = 50 minutes
9 = 60 minutes
40-
EXT
-04
-
A
SSOCIATED
L
OUD
B
ELL
:
0=Disabled 1=Use Relay on MSC Card
The system does not provide any voltage from the assigned relay. A separate ring voltage and ring device will
need to be provided by the installer.
40-
EXT
-05
-
P
AGING
A
CCESS
:
Stations will be able to page only if this option is enabled.
0=Enable 1=Disable