Operating instructions

TransTel TD-1648i / TDS-600 Programming Manual
111
Form 41 - Station Specifications
Item
Valid
Settings
Description
Default
41-st-01 1-8 Station Group / Agent Group for UCD 1=1
41-st-02 1-8 Key Group For KeyPhone 2=2
41-st-03 1-8 Shift Key Group For KeyPhone 0=None
41-st-04 1-8 Dial 9 trunk group 1=1
41-st-05 0-9 Toll plan - Day 0=0
41-st-06 0-9 Toll plan - Night 0=0
41-st-07 cn c = Card number, n = Port number
41-
EXT
-01
-
G
ROUP
A
SSIGNMENT
:
Zone Paging - Pick Up Group Station Group - Single Digit Dialing Group
1-8 = Valid Group Entries
41-
EXT
-02
-
F
LEXIBLE
K
EY
G
ROUP
(EKT):
(This assigns stations to one of 8 flexible keygroups.)
1-8 = Applicable Key Group From Form 07
41-
EXT
-03
-
SHIFT
K
EY
G
ROUP
(EKT):
Each station can have access to a second soft key group accessed by the [SHIFT] key (refer to Form 07). The
shift key must be programmed in the first group assigned to the station. When the shift key is used to access
the second group then it will light red and override the function assigned to it in the second group.
0 = Disabled 1-8 = Applicable Key Group From Form 07.
41-
EXT
-04
-
D
IAL
9
G
ROUP
:
When a station selects a trunk line by dialing 9, the system finds an available trunk according to the dial 9
group assignment. If a trunk is not in a station’s assigned dial 9 group then the station will not be able to make
outgoing calls on that trunk.
1-8 = Applicable Dial 9 Group From Form 36
41-
EXT
-05
-
T
OLL
P
LAN
(D
AY
S
ERVICE
):
This parameter assigns the toll plan to be used by the station in day mode.
Refer to Form 18 for Toll plan details.
0-9 = Applicable Toll Plan
41-
EXT
-06
-
T
OLL
P
LAN
(N
IGHT
S
ERVICE
):
This parameter assigns the toll plan to be used by the station in night mode. Refer to Form 18 for Toll plan
details
0-9 = Applicable Toll Plan
41-
EXT
-07
-
P
ORT
N
UMBER
:
This is for checking purposes only, the system will automatically show the
correct port number. It is not possible for the user to change or remove
this parameter.
This parameter is not user
programmable