Operating instructions
22 
Issue 1.0 March, 2006 
Site Requirements 
Location 
Choosing the Right Environment 
•  System should be installed in a clean, dry, secure location. This location must have adequate ventilation, 
and a temperature from 0   to 45  (32  to 113 ), with 10% to 95% non-condensing relative humidity. 
DO NOT install the equipment near sources of static electricity, excessive vibration, or water. Avoid direct 
sunlight. 
Installation Checklist 
INSTALLATION REQUIREMENTS  VERIFICATION 
MOUNTING SURFACE  Flat surface with adequate space for main cabinet, 
power supply, wiring and optional Battery Backup 
cabinet. 
AC LINE  AC line should be dedicated exclusively to the system. 
POWER OUTLET  Power Outlet must be a 
3-wire grounded outlet plug, having parallel blades 
and ground pin. 
Input power Line capacity requirements - 10 amperes. 
SURGE PROTECTION  A Surge Protector is recommended on the dedicated 
AC line. 
VENTILATION AND TEMPERATURE  Humidity: 10% to 95% relative non-condensing 
Temperature:32  to 113  (0   to 45  ). 
EARTH GROUND  A proper ground connection. (14 AWG) 
SERVICEABILITY  Lighting conditions and working space adequate for 
future service.
Equipment Requirements 
•  Unpack, Check and Verify Equipment - Unpack the telephone equipment boxes and verify the contents in 
accordance with the packing list provided. If any discrepancies are noticed, please contact TransTel or 
Authorized Dealers. 
•  Damaged Boxes - If you notice any damage to the packages, please notify both the shipper and TransTel or 
Authorized Dealers at once. 
•  List of parts included in basic KSU box: 
•  KSU Main Cabinet 
•  Power Supply 
•  Mounting Template 
•  Mounting Screws 
•  Station Quick Connectors 
•  Spare Fuses 
•  Cable Cover 