37
Access Control Telephone – ACP
Terminate the station wires with the connectors that are provided. The stations will connect to the G2-STU
of KSU. Connections are to the center two pins of the connector (pins 2 – 3).
Connect Tip/Ring terminals from KSU(G2-STU) to the ACP connector (6 contacts).
There is no polarity requirement on Tip and Ring.
Connect Relay for applications such like door open to the ACP connector (6 contacts).
Connect Sensor for applications such like door open alarm to the ACP connector (6 contacts).
Mount ACP connector on ACP itself.
Select the 1
st
or 2
nd
station. Jumper as below diagram showed.
Mount ACP on the wall.
CAUTION!: Avoid shorting Tip and Ring together. It may damage the G2-MBU or G2-STU board.