  Extended Passive Bus: 
d4: 500m ~ 800m; Length limitation by round trip delay 10us to 14us, not by attenuation.  
d5: 25m ~ 50m; Length limitation between TEs by differential round trip delay of 2us.   
Optional Cabling 
Connect a 6 conductor mounting cord from the 
KSU to a RJ-25 modular block. 
Door Switch (Relay) Connection 
 
One Door Switch (24+-12VDC) may be used 
on the TD-1648i/TDS-600 system. 
 
2-conductor wiring is required. 
 
Connect the door switch to pins 1 and 6 of 
the RJ-11 connector. 
Sensor Connection 
 
The Sensor connector on TD-1648i/TDS-600 
may be used for the External Sensor input. 
 
The sensor may be configured for normally 
open or normally closed operation. 
 
2-conductor wiring is required. 
 
Connect the sensor to pins 2 and 5 of the 
RJ-11 connector. 
 
Refer to System Programming Form 39 -- 
Sensor Assignment. 
Paging Connection 
 
The Paging connector on TD-1648i/TDS-600 
may be used for an External Paging input. 
 
2-conductor wiring is required. 
 
Connect the amplifier to pins 3 and 4 of the 
RJ-11 connector. 
Refer to Illustration Door Switch / Sensor / 
Paging cabling: 
Door switch/Sensor/Paging cabling 