Operating instructions
52 
Issue 1.0 March, 2006 
Form 05-01 Continued 
05-01-05
-
B
USY 
R
EMIND 
C
YCLE 
T
IME 
(O
FF
-H
OOK 
R
INGING
): 
This parameter selects the length of time an incoming trunk call rings the system before a busy ring 
assigned station is reminded of the call. A muted, one-second ring will be given to the station through 
the speaker to indicate the call. The tone will be repeated every busy remind time interval. 
This parameter also sets the timing for the SLT Camp-On feature (see Mode 05-08-03 to extend timing 
for SLT Camp on tone) and the camp on tone for key stations. 
0=0 seconds  1=2 seconds  2=4 seconds  3=6 seconds  4=8 seconds 
5=15 seconds  6=30 seconds  7=60 seconds  8=120 seconds  9=254 seconds 
05-01-06
-
P
AUSE 
T
IME
:
This parameter sets the system pause time duration for speed dial entry, trunk access time and voice 
mail call forwarding tone delay.. 
0=400 ms.  1=600 ms.  2=800 ms.  3=1000 ms.  4=1200 ms. 
5=1400 ms.  6=1600 ms.  7=1800 ms.  8=2000 ms.  9=2200 ms. 
05-01-07
-
DTMF
G
ENERATION 
T
IME
: 
This parameter permits the selection of DTMF Generation output time. The generation time may need 
to be lengthened to access some Voice Mail or answering machines. 
0=48 ms.  1=64 ms.  2=80 ms.  3=100 ms.  4=114 ms. 
5=132 ms.  6=156 ms.  7=164 ms.  8=180 ms.  9=196 ms. 
05-01-08
-
C
ALL 
F
ORWARD 
N
O 
A
NSWER 
T
RANSFER 
T
IME
: 
This parameter sets the duration between calling a station which has set call forward no answer, and 
the transfer of the call to the station to which it has been forwarded. 
0=10 seconds  1=20 seconds  2=30 seconds  3=40 seconds  4=50 seconds 