Operating instructions

54
Issue 1.0 March, 2006
05-02-05
-
K
EY
T
ELEPHONE
F
LASH
T
IMER
(
MS
.
=
MILLISECONDS
):
This parameter permits the selection of Flash time for Key stations when pressing the [TRF/FL]
key or an analog phone which presses flash and then dials 800 while connected to an outside line.
After dialing 800 the flash signal will be sent to the CO line and the analog phone will reconnect to
the line.
0=64 ms. 1=80 ms. 2=104 ms. 3=200 ms. 4=304 ms.
5=400 ms. 6=512 ms. 7=600 ms. 8=704 ms. 9=800 ms.
05-02-06
-
SLT
H
OLD
S
IGNAL
:
This parameter permits the selection of the Flash time from a single line telephone that the
system will see as a Hold signal if the time is greater than the hold signal but less than the SLT
release time.
DURING
CONVERSATION
HOOK PRESSED-Period B
HOOK RELEASED
Period B < SLT Release Time Hold
DURING
CONVERSATION
HOOK PRESSED-Period B
HOOK RELEASED
Period B > SLT Release Time Hang Up
0=64 ms. 1=80 ms. 2=104 ms. 3=200 ms. 4=304 ms.
5=400 ms. 6=512 ms. 7=600 ms. 8=704 ms. 9=800 ms.
05-02-07
-
M
INIMUM
R
ING
D
ETECTION
(R
ING
O
N
)
T
IMER
(
MS
.
=
MILLISECONDS
): Minimum ring burst that
must be present for the system to detect an incoming call.
0=160 ms. 1=200 ms. 2=280 ms. 3=400 ms. 4=480 ms.
5=600 ms. 6=680 ms. 7=800 ms. 8=880 ms. 9=1000 ms.
05-02-08
-
R
ING
C
YCLE
(R
ING
O
FF
)
T
IMER
: Length of time that the system must have without a ring
signal for the system to stop internal ringing (abandoned calls).
0=2 seconds 1=2 seconds 2=2 seconds 3=3 seconds 4=4 seconds
5=5 seconds 6=6 seconds 7=7 seconds 8=8 seconds 9=9 seconds