Operating instructions

56
Issue 1.0 March, 2006
05-03-05
-
T
OLL
A
CCESS
C
ODE
:
The first digit that is checked for verification of a toll call. This has no effect on toll restriction
within the system. It is only used to notify SMDR that a particular call is a toll call. See Form 14-01-
03.
In the United States, this parameter (if used) will generally be set to 1.
0=0 1=1 2=2 3=3 4=4
5=5 6=6 7=7 8=8 9=9
05-03-06
-
S
TATION
N
UMBER
D
IGIT
L
ENGTH
:
This assigns the number of digits used for the station numbering plan. 2, 3, or 4 digits may be used. In
the TD-824i the system will set this parameter to 2 digits automatically at the time of system
initialization
2=2 digit length 3=3 digit length 4=4 digit length
05-03-07
-
SLT
D
IAL
T
ONE
O
PTIONS
:
This parameter assigns the pattern of intercom dial tone and other “off hook” tones within the system.
Setting ICM Tone DND Tone CFWD Tone MSG Tone
0 Continuous Special Special Continuous
1 Interrupted Special Special Interrupted
2 Continuous Continuous Continuous Continuous
3 Interrupted Interrupted Interrupted Interrupted
4 Continuous Special Special Interrupted
5 Interrupted Special Special Continuousl
6 Continuous Continuous Continuous Interrupted
7 Interrupted Interrupted Interrupted Continuous
Continuous = Normal Dial tone Interrupted = Normal Busy Tone Special = Three Short Beeps
05-03-08
-
D
OORPHONE
R
INGING
F
REQUENCY
:
This parameter allows for different ring patterns for the Door Phone
0= continuous ringing 1~8 = ring frequency of the DK
telephone
9= Background Music