Operating instructions
56 
Issue 1.0 March, 2006 
05-03-05
-
T
OLL 
A
CCESS 
C
ODE
: 
The first digit that is checked for verification of a toll call. This has no effect on toll restriction 
within the system. It is only used to notify SMDR that a particular call is a toll call. See Form 14-01-
03. 
In the United States, this parameter (if used) will generally be set to 1. 
0=0  1=1  2=2  3=3  4=4 
5=5  6=6  7=7  8=8  9=9 
05-03-06
-
S
TATION 
N
UMBER 
D
IGIT 
L
ENGTH
:   
This assigns the number of digits used for the station numbering plan. 2, 3, or 4 digits may be used. In 
the TD-824i the system will set this parameter to 2 digits automatically at the time of system 
initialization 
2=2 digit length  3=3 digit length  4=4 digit length 
05-03-07
-
SLT
D
IAL 
T
ONE 
O
PTIONS
: 
This parameter assigns the pattern of intercom dial tone and other “off hook” tones within the system. 
Setting  ICM Tone  DND Tone  CFWD Tone  MSG Tone 
0  Continuous  Special  Special  Continuous 
1  Interrupted  Special  Special  Interrupted 
2  Continuous  Continuous  Continuous  Continuous 
3  Interrupted  Interrupted  Interrupted  Interrupted 
4  Continuous  Special  Special  Interrupted 
5  Interrupted  Special  Special  Continuousl 
6  Continuous  Continuous  Continuous  Interrupted 
7  Interrupted  Interrupted  Interrupted  Continuous 
Continuous = Normal Dial tone  Interrupted = Normal Busy Tone  Special = Three Short Beeps 
05-03-08
-
D
OORPHONE 
R
INGING 
F
REQUENCY
: 
This parameter allows for different ring patterns for the Door Phone 
0= continuous ringing  1~8 = ring frequency of the DK 
telephone 
9= Background Music 










