Operating instructions
TransTel TD-1648i / TDS-600 Programming Manual 
57
Form 05-04 - System Parameters Form - Codes-2 
Form 05-04-  01  02  03  04  05  06  07  08 
Item 
Range of Entries  0  0 - 1  0 - 2 
5 - 7 
0 - 1  0  0 - 4  0 - 1  1 - 2 
Default 
0  1  0  0  0  1  0  1 
Item 
Valid 
Settings 
Description 
Default 
05-04-01  0-7  RS232 Baud Rate  0=1200bps 
05-04-02  0-1  Dial 9 Flag  1=Enable 
05-04-03  0-8  Action for Call Duration Limiting  0=Warning 
05-04-04  0-1  12/24 Hours Clock  0=12 Hours 
05-04-05  0  Reserved  0 
05-04-06  2-4  Speed Dialing Distribution  1=200 Sets 
05-04-07  0-1  Single Digit Intercom  0=Disable 
05-04-08  0-4  Message Waiting Method – SLT Phones  1=Ring 
05-04-01
-
RS232
B
AUD 
R
ATE
: 
This parameter sets the baud rate for the RS232 port on G2-MSU card. This RS232 port can be 
used for SMDR, CTI signalling, MODEM for remote programming purpose. 
Caution: High baud rate could cause system low performance for other applications. 
0 = 1200  1 = 2400  2 = 3600  3 = 4800 
4 = 9600  5 = 19200  6 = 38400  7 = 56000 (bps) 
05-04-02
-
D
IAL 
9
(H
YBRID
)
A
CTIVATION 
T
URNS ON 
D
IAL 
9
(
POOLED 
CO
 LINES
): 
This parameter sets if a station can access an outgoing line by dialing 9. If this parameter is 
disabled the station can still access an outgoing line by pressing a line key 
0=Dial 9 access Disabled  1= Dial 9 access Enable 
05-04-03
-
C
ALL 
L
IMIT 
T
YPE
: 
This parameter decides what action will be taken if a station has limit call duration enabled in 
Mode 40-nnnn-03. Settings 0 to 3 are for outgoing calls only. The outside party will also hear the 
warning tone. 
0=Continuous Warning After Timeout (Outgoing). 
1=1 Second Warning at Duration Limit (Outgoing). 
2=1 Second Tone 10 seconds Prior to Timeout. Continuous Tone 5 seconds prior. 
Line is released at Timeout (Outgoing). 
5=Same as 1 above, except affects both Incoming and Outgoing. 
6=Same as 2 above, except affects both Incoming and Outgoing. 
7=Same as 3 above, except affects both Incoming and Outgoing. 
05-04-04
-
T
IME 
F
ORMAT 
D
ISPLAY
: 
0=12 Hour Clock (AM/PM)  1=24 Hour Clock 00:00-23:59 