Operating instructions

TransTel TD-1648i / TDS-600 Programming Manual
57
Form 05-04 - System Parameters Form - Codes-2
Form 05-04- 01 02 03 04 05 06 07 08
Item
Range of Entries 0 0 - 1 0 - 2
5 - 7
0 - 1 0 0 - 4 0 - 1 1 - 2
Default
0 1 0 0 0 1 0 1
Item
Valid
Settings
Description
Default
05-04-01 0-7 RS232 Baud Rate 0=1200bps
05-04-02 0-1 Dial 9 Flag 1=Enable
05-04-03 0-8 Action for Call Duration Limiting 0=Warning
05-04-04 0-1 12/24 Hours Clock 0=12 Hours
05-04-05 0 Reserved 0
05-04-06 2-4 Speed Dialing Distribution 1=200 Sets
05-04-07 0-1 Single Digit Intercom 0=Disable
05-04-08 0-4 Message Waiting Method – SLT Phones 1=Ring
05-04-01
-
RS232
B
AUD
R
ATE
:
This parameter sets the baud rate for the RS232 port on G2-MSU card. This RS232 port can be
used for SMDR, CTI signalling, MODEM for remote programming purpose.
Caution: High baud rate could cause system low performance for other applications.
0 = 1200 1 = 2400 2 = 3600 3 = 4800
4 = 9600 5 = 19200 6 = 38400 7 = 56000 (bps)
05-04-02
-
D
IAL
9
(H
YBRID
)
A
CTIVATION
T
URNS ON
D
IAL
9
(
POOLED
CO
LINES
):
This parameter sets if a station can access an outgoing line by dialing 9. If this parameter is
disabled the station can still access an outgoing line by pressing a line key
0=Dial 9 access Disabled 1= Dial 9 access Enable
05-04-03
-
C
ALL
L
IMIT
T
YPE
:
This parameter decides what action will be taken if a station has limit call duration enabled in
Mode 40-nnnn-03. Settings 0 to 3 are for outgoing calls only. The outside party will also hear the
warning tone.
0=Continuous Warning After Timeout (Outgoing).
1=1 Second Warning at Duration Limit (Outgoing).
2=1 Second Tone 10 seconds Prior to Timeout. Continuous Tone 5 seconds prior.
Line is released at Timeout (Outgoing).
5=Same as 1 above, except affects both Incoming and Outgoing.
6=Same as 2 above, except affects both Incoming and Outgoing.
7=Same as 3 above, except affects both Incoming and Outgoing.
05-04-04
-
T
IME
F
ORMAT
D
ISPLAY
:
0=12 Hour Clock (AM/PM) 1=24 Hour Clock 00:00-23:59