Form 14 - Station Message Detail Recording 
Form 14 -01- 
01  02  03  04  05  06  07  08 
Item                 
Options  0-9  0-1  0-1  0-1  0-1  00-99  0  0-1 
Default 
0  0  0  0  0  21  0  0 
Item  Valid Settings  Description  Default 
14-01-01  0-9  Call Duration Start Time  0=00 Sec. 
14-01-02  0-1  Record Incoming Call  0=Record 
14-01-03  0-1  Record Local Call  0=Record 
14-01-04  0-1  Record Incoming Call No Answer  0=Record 
14-01-05  0-1  Print out the Title  0=Yes 
14-01-06  00-99  Number of records between titles  21=21 
14-01-07  0  Reserved  0= 
14-01-08  0-3  Polarity Reversal  0=No 
14-01-01
-
R
ECORDING 
S
TART 
T
IME
: 
This parameter determines a “grace period” before call costing begins. This allows for calls that 
are made but unanswered. Calls that last less than the amount of time specified in this parameter 
will not be reported via the SMDR port. 
0=immediate 
start 
1=5 seconds  2=10 seconds  3=15 Seconds  4=20 Seconds 
5=25 Seconds  6=30 Seconds  7=35 Seconds  8=40 Seconds  9=45 Seconds 
14-01-02
-
R
ECORD 
I
NCOMING 
C
ALLS
: 
This parameter determines if inbound calls generate a record via SMDR 
0=Enable (Record Incoming Calls)  1=Disable (Do Not Record Incoming Calls) 
14-01-03
-
R
ECORD 
C
ALLS 
L
OCAL 
C
ALLS 
(N
O 
T
OLL 
A
CCESS 
C
ODE
): 
Outbound calls that begin with the toll access code programmed on Form 05-03-05 are considered 
toll calls in this parameter. If this option is enabled, calls that do not begin with the selected toll 
code, they will still be recorded via SMDR. If this option is disabled, calls do not begin with the toll 
access code in 05-03-05 will not be recorded via SMDR. 
0=Enable (Record local calls)  1=Disable (Do Not Record local calls) 
04-01-04
-
R
ECORD 
U
NANSWERED 
I
NCOMING 
C
ALLS
: 
This parameter determines if an unanswered incoming call is recorded via SMDR. 
0=Enable 
(Record Unanswered Incoming Calls) 
1=Disable 
(Does Not Record Unanswered Incoming Calls) 
14-01-05
-
P
RINT 
P
AGE 
H
EADER
: 
This parameter decides whether the system will output the description of each column. 
0=Enable  1=Disable 