Use and Care Manual

7
17 590 28 Rev. A
KohlerEngines.com
EN
Oil Recommendations
All-season KOHLER
®
PRO 10W-50 Synthetic
Oil is the ideal oil for KOHLER engines. It is
speci cally formulated to extend the oil change
interval to 300 Hours. Contact your Kohler
authorized dealer for availability.
300-Hour oil change intervals are exclusive to
and only authorized on KOHLER engines that
utilize the KOHLER PRO 10W-50 Synthetic
Oil. Alternative engine oils may be used with
KOHLER engines but require 100-Hour oil
change intervals for proper maintenance. Oil
must be API (American Petroleum Institute)
service class SJ or higher. Select viscosity
based on air temperature at time of operation
as shown below.
Change Oil
Change oil while engine is warm.
1. Clean area around oil ll cap/dipstick and
drain plug.
2. Remove drain plug and oil ll cap/dipstick.
Drain oil completely.
3. Reinstall drain plug. Torque to 13 ft. lb.
(17.6 N·m).
4. Fill crankcase with new oil to speci ed level
on dipstick or ller neck threads for engine
being serviced. See Check Oil Level.
5. Reinstall oil ll cap/dipstick and tighten
securely.
6. Dispose of used oil in accordance with local
ordinances.
Oil Sentry
(if equipped)
This switch is designed to prevent engine
from starting in a low oil or no oil condition. Oil
Sentry
may not shut down a running engine
before damage occurs. In some applications
this switch may activate a warning signal. Read
your equipment manuals for more information.
Reduction Systems (if equipped)
Some engines are equipped with a gear
reduction system. Follow maintenance and oil
change information speci ed in this section and
maintenance schedule.
2:1 Reduction System (CH270)
This reduction system is lubricated by engine
crankcase oil. No special maintenance or
service is necessary. Check and maintain
engine oil level as outlined in Check Oil Level.
2:1 with Clutch Reduction System (CH245,
CH255, CH270, CH395, CH440)
NOTE: Engines with this reduction system
must be operated at 2400 RPM or
higher under load, when full gear box
engagement occurs. Operating engine
under heavy loads below 2400 RPM,
could result in clutch/gear box failure
from disc slippage/overheating and
insu cient engine cooling, not covered
under normal warranty.
This reduction system uses a clutch assembly
and chain and sprocket drive system,
independent of, and separated from main
crankcase lubrication. Check and maintain oil
level using dipstick in gear box case. Change
reduction system oil at interval in maintenance
schedule. Use 20W-40 or 20W-50 oil in this
gear box case. Oil capacity of this gear box is
0.5 L (0.52 U.S. qt.).
1. Drain old oil out through oil drain plug of gear
box cover, tip engine as required. Reinstall
drain plug and tighten securely.
°F -20 0 20 32 40 60
50 80 100
°C -30 -20 -10 0 10 20 30 40
5W-30
10W-30
SAE 30
KOHLER PRO 10W-50
Check Oil Level
NOTE: To prevent extensive engine wear or
damage, never run engine with oil level
below or above operating range
indicator on dipstick.
Ensure engine is cool and level. Clean oil ll/
dipstick areas of any debris.
1. Remove dipstick; wipe oil o .
2. Reinsert dipstick into tube; rest on oil ll
neck; turn counterclockwise until cap drops
down to lowest point of thread leads; do not
thread cap onto tube.
a. Remove dipstick; check oil level.
For CH260/CH270 engines, oil level
should be at middle of indicator on
dipstick.
For all other models, oil level should be
at top of indicator on dipstick.
or
b. Remove oil ll plug.
For CH260/CH270 engines, oil level
should be to middle of ller neck threads.
For all other models, oil level should be
up to point of over owing ller neck.
3. If oil is low, add oil to speci ed level on
dipstick or ller neck threads for engine being
serviced. See step 2.
4. Reinstall dipstick or oil ll plug and tighten
securely.