Owner’s Manual Model 9150 Vehicular Slide Gate Operator DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 9150-065 REV B, 7/01 Copyright 2000 DoorKing, Inc. All rights reserved.
ii
Use this manual with the following models only. Models 9150-080, 9150-081, 9150-082, 9150-083, 9150-084, 9150-085, 9150-086, 9150-087, 9150-088, 9150-089, 9150-090, 9150-091 slide gate operators with circuit board 4602-010. NOTE: Models 9150-082, 9150-083, 9150-085, 9150-086, 9150-087, 9150-091 will have a supplemental manual (P/N 2340-065) that describes the operation and setup of the optional battery backup system available with these units, and provides additional wiring information for these units.
IMPORTANT NOTICES Vehicular gate systems provide convenience to their users and limit vehicular traffic onto your property. These systems can produce high levels of force; therefore it is important that you are aware of possible hazards associated with your gate operating system. These hazards may include pinch points, entrapment, absence of controlled pedestrian access or traffic backup. Be sure that the installer has instructed you on the proper operation of the gate and gate operator system.
IMPORTANT SAFETY INSTRUCTIONS WARNING - To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate or play with gate controls. Keep the remote control away from children. 3. Always keep people and objects away from gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. 4. Test the operator monthly. The gate MUST reverse on contact with a rigid object or stop or reverse when an object activates the non-contact sensors.
RESTRICTIONS AND WARNINGS Install The Gate Operator Only If: The operator is appropriate for the usage Class of the application and the gate is within the weight and length limitations specified for the operator. • All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet (1.2 m) above the ground to prevent a 2 ¼ inch (57.
ENTRAPMENT PROTECTION This vehicular gate operator is equipped with an inherent (Type A) entrapment sensing system. This system will sense an obstruction in both the opening and closing gate cycles, and will cause the gate to reverse direction should an obstruction be encountered. If the system detects a second obstruction before reaching the full open or close limit after the initial reversal, an alarm will activate and the operator will require a reset before resuming normal operation.
GLOSSARY GATE – A moving barrier such as a swinging, sliding, raising, lowering, or the like, barrier, that is a stand-alone passage barrier or is that portion of a wall or fence system that controls entrance and/or egress by persons or vehicles and completes the perimeter of a defined area. RESIDENTIAL VEHICULAR GATE OPERATOR-CLASS I - A vehicular gate operator (or system) intended for use in a home of one-to four single family dwelling, or garage or parking area associated therewith.
TABLE OF CONTENTS Section 1 – Installation 1.1 Specifications ....................................................................................................................................... 1 1.2 Mounting Positions 1.2.1 1.3 1.4 1.5 Front Position Post Mount .................................................................................................... 2 1.2.3 Rear Position Pad or Post Mount.......................................................................................... 3 1.
Section 4 – Operating Instructions 4.1 Power and Reset Switches................................................................................................................... 31 4.2 Shutdown Conditions 4.2.1 4.3 Soft Shutdown ...................................................................................................................... 32 4.2.2 Resetting a Soft Shutdown ................................................................................................... 32 4.2.
SECTION 1 - INSTALLATION Prior to beginning the installation of the slide gate operator, we suggest that you become familiar with the instructions, illustrations, and wiring guide-lines in this manual. This will help insure that your installation is performed in an efficient and professional manner. The proper installation of the vehicular slide gate operator is an extremely important and integral part of the overall access control system.
1.2 MOUNTING POSITIONS The Model 9150 operator is designed so that it can be installed in any of the mounting positions shown below. Once the mounting position has been determined, the chain idlers must be adjusted to accommodate the mounting position chosen before the operator is mounted to the pad or post. The idlers are factory set for the front, pad mount position. (Note: Rear and center position, and postmounted operators require additional hardware not supplied with the operator).
1.2.3 REAR POSITION PAD OR POST MOUNT • Set one chain idler at the top position and one chain idler at the center position on the same side of the operator. • Remove the top and bottom chain knockouts from the side of the operator. • Chain enters and exits the operator from the same side. Chain is attached to one end of the gate. • This mounting method hides the chain when looking at the gate from the front. • ADDITIONAL HARDWARE REQUIRED: Endless Idler Assembly P/N 2600-818.
1.3 MOUNTING OPTIONS Pad mounting can be used when the operator will be installed using either the front or rear mounting position. If the operator is to be center mounted, the post mounting method must be used. 1.3.1 PAD MOUNTED OPERATORS 1. Construct a form for the mounting pad according to the specifications shown in figure 6. Be sure to level the top edge of the form and that the top of the form is a minimum of four (4) inches above ground level.
1.3.2 POST MOUNTED OPERATORS Post mounting can be used when the operator will be installed in any of the three mounting positions, and must be used if the operator is to be center mounted. Gate 1. Post mounting the operator requires the use of an operator base plate (P/N 2600-495) and two (2) 6 X 6 steel post (not supplied) welded to the base plate as shown in figure 7.
1.4 OPERATOR INSTALLATION Prior to mounting the gate operator, be sure that the chain knockouts and chain idlers are set for the mounting position (front, center or rear) and the mounting option chosen (pad or post). Refer back to SECTION 1.2. 1.4.1 PAD MOUNTED OPERATORS • Position the operator on the pad so that there is a minimum clearance of one (1) inch between the back of the operator housing and the gate.
1.5 CHAIN INSTALLATION 1.5.1 FRONT – PAD MOUNT 1. Secure the chain brackets to each end of the gate so that the brackets are level with the top chain knockouts in the operator housing. Brackets should be attached to the inside of the frame so that the chain bolts, when attached, do not protrude beyond the frame of the gate (figure 10). 2. Route the chain through the gate operator: over the chain guide idlers and under the drive sprocket (figure 12). 3.
1.5.2 FRONT – POST MOUNT 1. Secure the chain brackets to each end of the gate so that the brackets are level with the bottom chain idlers in the operator housing. Brackets should be attached to the inside of the frame so that the chain bolts, when attached, do not protrude beyond the frame of the gate. 2. Route the chain through the gate operator: under the chain guide idlers and over the drive sprocket (Figure 15). 3. Slide each end of the chain through a chain stop (optional).
1.5.3 REAR – PAD OR POST MOUNT 1. Install an endless idler assembly (p/n 2600-818) at the gate opening between the gate and fence (figure 16, 18). Note that the chain is routed between the fence and the gate in this type of installation. IMPORTANT!! Be sure that the idler assembly is securely attached to the gatepost, pilaster, etc. 2. Secure the chain brackets to the gate as shown in figure 16. The chain brackets should be attached to the gate frame so that they are approximately one (1) inch apart. 3.
1.5.4 CENTER – POST MOUNT 1. Install an endless idler assembly (p/n 2600-818) at each end of the gate opening (figure 21). Note that the gate travels between the fence and the chain in this type of installation. IMPORTANT!! Be sure that the idler post/mount assembly is secure. 2. Secure the chain brackets to the gate as shown in figure 19. The chain brackets should be attached to the gate frame so that they are approximately one (1) inch apart. 3.
1.6 WARNING SIGN INSTALLATION This DoorKing slide gate operator is shipped with two warning signs. The purpose of the warning signs is to alert uniformed persons, and to remind persons familiar with the system, that a potential hazard may exist so that appropriate action can be taken to avoid the hazard or to reduce exposure to the hazard. 1. Permanently install the supplied warning signs in locations so that the signs are visible by persons on both sides of the gate. 2.
12
SECTION 2 – WIRING Before attempting to connect any wiring to the operator, be sure that the circuit breaker in the electrical panel is in the OFF position. Permanent wiring must be installed to the operator as required by local electrical codes. It is recommended that such work be performed by a licensed electrical contractor.
2.1 HIGH VOLTAGE CONNECTIONS Use Table 1 to determine high voltage wire size requirements. The distance shown in the chart is measured in feet from the operator to the power source. If power wiring is greater than the maximum distance shown, it is recommended that a service feeder be installed. When large gauge wire is used, a separate junction box must be installed for the operator connection. The wire table is based on stranded copper wire.
2.2 CONTROL WIRING Controls must be far enough from the gate so that the user is prevented from coming in contact with the gate while operating the controls. Outdoor or easily accessible controls should have a security feature to prevent unauthorized use. • Connect optional control devices to the operator terminal strip as shown in figure 25. Be sure that all electrical connections are made in accordance with local electrical codes. Use 18 AWG wire for all low voltage wiring, maximum distance 3000 feet.
2.3 SECONDARY ENTRAPMENT PROTECTION DEVICE WIRING Secondary entrapment protection devices must be installed to insure a safe operating environment and to reduce the risk of entrapment. This operator has inputs for non-contact sensors and contact sensors for both opening and closing gate cycles. Secondary entrapment protection may be provided by a combination of both type sensors. See Section 5.3 for a list of acceptable secondary entrapment protection devices. 2.3.
2.3.2 CONTACT SENSORS • Disconnect power to the gate operator before installing the contact sensors. • Connect the contact sensors as shown below to the auxiliary terminal strip located on the 4602 control board. • Contact sensors must be located at the leading edge, trailing edge, and post mounted both inside and outside of the vehicular sliding gate. Additional contact sensors may be added for additional protection where an entrapment zone may exist.
2.4 LOOP DETECTOR WIRING Loops and loop detectors must be installed with this gate operator to prevent the gate from accidentally closing on vehicles that may be in the path of the gate. • Loop detector wiring is shown for DoorKing model 9406 Plug-In loop detector only. If other loop detectors are used, refer to the installation instructions supplied with those detectors for wiring requirements. • If other loop detectors are used, all inputs to the terminal strip are NORMALLY OPEN.
2.5 GATE TRACKER™ CONNECTIONS This gate operator is equipped with outputs from the circuit board that will report operator status to a companion DoorKing Access Control System (Model 1803PC, 1815, 1817 or 1818) when equipped with an optional Tracker expansion board. This report includes items such as gate operator cycle count, any shorted inputs, loop detector problems, any attempts to force the gate open, if the gate has struck anything during the open or close cycle, power interruptions, etc.
2.6.1 ALARM RESET SWITCH The gate operator is equipped with a reset switch that will silence the entrapment alarm and return the operator to normal operation after a hard shutdown occurs. An auxiliary reset button may be added provided that the following condition is met. • The alarm-reset button must be located in the line of sight of the gate. • Connect the normally open alarm-reset switch to auxiliary terminals 11 and 18.
2.7 MASTER / SLAVE WIRING 2.7.1 OPERATOR INTERFACE The interface wiring between the two operators requires four (4) 18 AWG wires for control plus two (2) additional 18 AWG wires for secondary entrapment protection device connection. Each operator must be connected to it's own power source as described in section 2.2. The loop functions are controlled by a two-channel loop detector (P/N 9404-010) plugged into the OPEN port on the operator that is designated as the master unit. 1.
2.7.2 SECONDARY ENTRAPMENT PROTECTION DEVICE WIRING Secondary entrapment protection for slide gate operators connected in a master / slave configuration will require three sets of photo-beams to insure protection. • One photo-beam is directed across the roadway and connected to the CLOSE photo-beam input on the auxiliary terminal strip of both the master and slave operator. This photo-beam is active in the close direction only and will not affect the movement of the gates while the gates are opening.
2.8 TERMINAL IDENTIFICATION AND DESCRIPTION 2.8.1 MAIN TERMINAL 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. RADIO RECEIVER LOW VOLTAGE COMMON RADIO RECEIVER FULL OPEN INPUT RADIO RECEIVER 24 VAC POWER – 250-ma MAX FULL OPEN / CLOSE INPUT When gate is closed, input will open gate to full position. When gate is open and auto close timer is turned on, input will re-set and hold timer. When gate is open and auto close timer is turned off, input will close gate.
2.8.2 AUXILIARY TERMINAL The auxiliary terminal is located on the 4602 circuit board just to the right of main terminals 8 and 9. Auxiliary terminals are numbered 1 through 5 with the first terminal at the top. 1. OPEN PHOTO-BEAM This input is only active when the gate is in the opening cycle. An open photo-beam input during the opening cycle will cause the gate to stop. The gate will remain stopped until the photo-beam input is cleared, at which time the gate will resume the open cycle. 2.
SECTION 3 - ADJUSTMENTS The switch settings and adjustments in this chapter should be made after your installation and wiring to the operator(s) is complete. Whenever any of the programming switches on the circuit board are changed, power must be shut-off, and then turned back on for the new setting to take effect. 3.1 CIRCUIT BOARD ADJUSTMENTS • Set the DIP-switches on the circuit board to the desired setting. See switch-setting charts in section 3.2.
3.2 SWITCH SETTINGS The two DIP-switches located on the circuit board are used to program the operator to operate in various modes and to turn on or off various operating features. Whenever a switch setting is changed, power to the operator must be turned OFF and then turned back on for the new setting to take affect. Check and review ALL switch settings prior to applying power to the operator. SW 1 (LEFT SWITCH) SWITCH FUNCTION SETTING 1 Direction OFF ON Changes open / close direction of operator.
3.2.1 SW 1 (LEFT SWITCH) DESCRIPTION AND FUNCTION Switch 1: Set so that the operator cycles open upon initial power up and open command. If the operator cycles close, turn power off and change the setting on this switch. Switch 2: Turns the auto close timer on or off. Set from 1 to 23 seconds. Switch 3: This switch should be left in the OFF position when the slide gate is running on a level track and the gate does not coast.
3.3 AUTOMATIC LIMIT ADJUSTMENT This gate operator does not use any mechanical limit switches or run timers to adjust the open and close positions of the gate. The gate open and close positions are determined by the physical stops (or chain stops) of the gate. The gate operator will automatically measure the gate and will set its "limits" from this measurement during this automatic sequence.
3.4 INHERENT REVERSE ADJUSTMENT This vehicular gate operator is equipped with an inherent (Type A) entrapment sensing system. This system will sense an obstruction in either the opening or closing gate cycles and will cause the gate to reverse direction should an obstruction be encountered. For this system to function correctly, the gate must be properly installed and work freely in both directions. A good set of ball bearing wheels (or rollers) is essential for proper slide gate operation. 3.4.
3.4.2 CLUTCH ADJUSTMENT In addition to the reverse sensitivity adjustment, this operator is equipped with a mechanical slip clutch to further reduce the possibility of injury should an entrapment occur. Do not over tighten the clutch in this gate operator to compensate for a damaged or poorly constructed gate, or to compensate for a gate that is too heavy or that has damaged wheels or rollers. Doing this can create a hazard which can result in serious injury or death to persons who may become entrapped. 1.
SECTION 4 – OPERATING INSTRUCTIONS WARNING - To reduce the risk of injury or death: 1. 2. 3. 4. 5. 6. 7. 8. READ AND FOLLOW ALL INSTRUCTIONS. Never let children operate or play with gate controls. Keep the remote control away from children. Always keep people and objects away from gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE Test the operator monthly. The gate MUST reverse on contact with a rigid object or stop or reverse when an object activates the non-contact sensors.
4.2 SHUTDOWN CONDITIONS Under various entrapment conditions the operator will assume either a soft or hard shutdown (alarm) condition. To determine what type of reset action is required, you will need to understand how the different entrapment conditions affect the gate operator. 4.2.1 SOFT SHUTDOWN This occurs in various situations where the inherent or secondary entrapment protection devices have been activated.
4.2.3 HARD SHUTDOWN A hard shutdown condition occurs when the inherent entrapment protection system has sensed two consecutive obstructions before the gate reaches the full open or full closed position. • Example: The gate is closing and the inherent entrapment protection system senses an obstruction and causes the gate to reverse direction. As the gate begins to run in the open direction, a second obstruction is sensed prior to the gate reaching the full open position.
4.3 MANUAL / EMERGENCY GATE OPERATION This operator is equipped with a manual release system that will allow the gate to be pushed open in the event of a power outage or equipment failure. There are two manual release systems that are available on this gate operator. The standard type release is the FAIL-SAFE system (required by many city codes), while an optional release is the FAIL-SECURE system.
4.3.3 FAIL-SECURE MANUAL OPERATION The FAIL-SECURE option locks the gate when primary (AC) power is removed and requires a keyed release to place the gate in manual operation. The FAIL-SECURE option is typically used in CLASS III and CLASS IV applications. • Be sure that primary (AC) and backup (DC) power is removed or shut-off prior to placing the gate operator in manual operation. • Insert the manual release key into the keyed release on the side of the gate operator, and turn it clockwise 1/4 turn.
36
SECTION 5 – MAINTENANCE AND TROUBLESHOOTING Inspection and service of this gate operator by a qualified technician should be performed anytime a malfunction is observed or suspected. High cycle usage may require more frequent service checks. 5.1 MAINTENANCE When servicing the gate operator, always check any secondary (external) reversing devices (loops, photo eyes, etc.) for proper operation.
5.2 TROUBLESHOOTING Have a good VOM meter to check voltages and continuity. A Meg-Ohm meter capable of checking up to 500 meg-ohms of resistance is necessary to properly check the integrity of the ground loops. When a malfunction occurs, isolate the problem to one of three areas: 1) the operator, 2) the loop system, 3) the keying devices. Use caution when checking high voltage terminals, motor capacitor and the motor. 1. Check the input indicator LEDs.
Gate opens a short distance, then stops and reverses. Gate opens but will not close. Gate closes but will not open. Gate starts to close, then reverses to open. Gate closes and then re-opens. Entrapment alarm is sounding. Operator will not run. Entrapment alarm sounds a short beep every 5 seconds. • Check that the clutch is adjusted properly and is not slipping. • Disconnect the gate from the gate operator and check that the gate slides freely without any binding.
MOTOR / BELT ACCESS To gain access to the inside of the gate operator, loosen the two bolts on each side of the electrical panel at the bottom. The entire panel can then swing up for easy access into the operator. Loosen Loosen CAUTION!! Be sure power is OFF before accessing the inside of the operator. Be sure that the electrical panel is secured in the up position - it will not stay in this position by itself.
5.3 ACCESSORIES The following accessory items can be used with the model 9100 slide gate operator. Contact Sensor Photo Cell Loop Detector Loop Wire Pre-Fab Loops Loop Test Meter Control Station Time Clock Surge Devices Gate Scale Speed Bumps Endless Idler Base Plate Nickel Chain Stainless Chain Contact sensors for use as a secondary entrapment protection device. Miller Edge, Inc. ME120, ME123, MG020, MGR20, MGS20 Non-contact (photo cells) sensors for use as a secondary entrapment protection device.
Black White Green Convenience Outlets Ground Black Black White Power Switch Lock Solenoid White Motor Capacitor Red Blue Circuit Board High Voltage Terminals 1/2 HP Motor Black Resistor Resistor White Red Blue Red Reset Switch Entrapment Alarm 11 12 18 42 120 VAC Power Blue Brown Main Terminals Black White Green 120 VAC 1/2 HP
Black White Green Convenience Outlets White Black Black Ground Power Switch Lock Solenoid White Black Orange Resistor Yellow 1 HP Motor Yellow Resistor White Orange Circuit Board High Voltage Terminals Green White Black Blue Resistor Red Resistor Blue Red Brown Reset Switch Main Terminals 120 VAC Power Entrapment Alarm 11 12 18 43 120 VAC 1 HP
Black White Green Convenience Outlets White Black Ground Blue Red Power Switch Power Transformer Green Motor Capacitor Red Lock Solenoid Blue Circuit Board High Voltage Terminals White White 1/2 HP Motor Black Resistor Resistor White Blue Red Blue Red 230 VAC 1/2 HP Brown Reset Switch Main Terminals 230 VAC Power Entrapment Alarm 11 12 18 44
Black White Green Convenience Outlets White Black Ground Blue Red Power Switch Power Transformer White Orange Resistor Yellow Yellow White White Black Blue Resistor Red Brown Resistor Blue 230 VAC 1 HP Entrapment Alarm 11 12 18 45 230 VAC Power Red Lock Solenoid Reset Switch Main Terminals 1 HP Motor Resistor Orange Circuit Board High Voltage Terminals Green
Black White Green Convenience Outlets White Black Ground Blue Red Power Switch Power Transformer Green Motor Capacitor Red Lock Solenoid Blue Circuit Board High Voltage Terminals White White 1/2 HP Motor Black Resistor Resistor White Blue Red Blue Red 230 / 460 VAC 3-phase 1/2 HP Brown Reset Switch Main Terminals 230 / 460 VAC 3-phase Power Entrapment Alarm 11 12 18 46
Black White Green Convenience Outlets White Black Ground Blue Red Power Switch Power Transformer White Orange Resistor Yellow Yellow White White Black Blue Resistor Red Brown Resistor Blue 230 / 460 VAC 3-phase 1 HP Entrapment Alarm 11 12 18 47 230 / 460 VAC 3-phase Power Red Lock Solenoid Reset Switch Main Terminals 1 HP Motor Resistor Orange Circuit Board High Voltage Terminals Green