User`s manual

Optical Fiber Amplifier Users Manual
Rev.1.2 1U-Shelf Series November 2007
ping O O
logout O O
ip Read/Write Read Only
subnetmask Read/Write Read Only
gateway Read/Write Read Only
initsys O X
reset O O
mpu Read/Write Read Only
otu Read/Write Read Only
ofau Read/Write Read Only
snmp Read/Write Read Only
log Read/Write Read Only
timesync O X
5.1.1.1 VER
Software version information.
ex)
[ADMIN]# VER
+-------------------------------------------------+
| Otical Amplifier Shelf System |
| Debug Console Mode |
| |
| SNMP Board ver 1.0 |
| |
| S/W Ver : 01.00.00.00 Update : 2006/12/11 |
+-------------------------------------------------+
5.1.1.2 CLS
Clear console screen.
5.1.1.3 PING
Confirm IP address to see if the IP address is assigned to any physical device.
ex)
[ADMIN]# PING 192.168.0.1
192.168.0.1 is alive.
5.1.1.4 LOGOUT
Log out from RS-232 interface. Not applicable for SNMP connection.
5.1.1.5 IP
View or set up IP Address. Avoid IP address collision by using a unique IP address.
5.1.1.6 SUBNETMASK
View or set up SubnetMask Address. Check network connection configuration before set up.
5.1.1.7 GATEWAY
View or set up Gateway Address. Confirm Gateway address of connected network before set up.
5.1.1.8 INITSYS
Initialize the product with factory default setup. Note that all the configurations, including log
information, are to be initialized.
5.1.1.9 RESET
Reset network connections for configuration change or any other needs for connection reset.
OFAU operation is not affected by this command. Only network connection is to be reset.
5.1.1.10 MPU