System information

Program 12 : Night Mode Setup
12-02 : Automatic Night Service Patterns
UX5000 Software Program Manual Programming 167
12-02 : Automatic Night Service Patterns
Description
Use Program 12-02 : Automatic Night Service Patterns to dene the daily pattern of the auto
night switch setting. Each Night Mode Group has 10 patterns. These patterns are used in Programs
12-03 and 12-04. The daily pattern consists of 20 timer settings.
Input Data
Example:
Time Pattern 1
To make the above schedule, it is necessary to set the data as follows:
Level:
Feature Availability
SA Available.
Night Mode Service Group Number 01-32
Time Pattern Number 01-10
Set Time Number 01-20
Item Description Input Data
01 Start Time 0000-2359
02 End Time 0000-2359
03 Operation Mode 1-8
0:00 9:00 12:00 13:00 17:00 18:00 22:00 0:00
Mode 3 Mode 1 Mode 4 Mode 1 Mode 4 Mode 2 Mode 3
(midnight) (day) (rest) (day) (rest) (night) (midnight)
Time setting 01: 00:00 to 09:00 Mode 3 (midnight)
Time setting 02: 09:00 to 12:00 Mode 1 (day)
Time setting 03: 12:00 to 13:00 Mode 4 (rest)
Time setting 04: 13:00 to 17:00 Mode 1 (day)
Time setting 05: 17:00 to 18:00 Mode 4 (rest)
Time setting 06: 18:00 to 22:00 Mode 2 (night)
Time setting 07: 22:00 to 00:00 Mode 3 (midnight)