System information

Program 25 : VRS/DISA Setup
25-07 : System Timers for VRS/DISA
480 Programming UX5000 Software Program Manual
Conditions
None
Feature Cross Reference
Direct Inward System Access (DISA)
08 Long Conversation Disconnect
This timer determines how long the UX5000 will wait before dis-
connecting a DISA caller or any trunk-to-trunk (such as Tandem
Trunking) conversation call after the Long Conversation tone is
heard.
This program has no affect if Program 25-07-07 is set to "0".
0-64800
seconds
10 14-01-25
20-28-01
20-28-02
20-28-03
20-31-20
25-07-07
09 DISA Internal Paging Time
This is the maximum length of an Internal Page placed by a DISA
caller. If the Page continues longer than this interval, the UX5000
terminates the DISA call.
0-64800
seconds
30 20-31-21
10 DISA External Paging Time
This is the maximum length of an External Page placed by a DISA
caller. If the Page continues longer than this interval, the UX5000
terminates the DISA call.
0-64800
seconds
30 20-31-22
11 VRS/DISA Answer Delay Timer
Set up the interval time the UX5000 will wait after receiving an
incoming VRS/DISA call until the UX5000 will automatically
answer the call.
0-64800
seconds
0
13 VRS/DISA Busy Tone Interval
If a DISA caller dials a busy extension (and Program 25-04 = 0),
the UX5000 plays busy tone for this interval before disconnecting.
0-64800
seconds
5
14 Delayed DID Answer Timer
Assign the delay time from switching from a normal incoming sta-
tus to DID mode. If this time is set to ‘0’, the call will switch to
DID mode immediately.
0-64800
seconds
10
Item
No.
Item Input Data Default
Related
Program