Operation Manual

Crossovers
Input Level control
The input level control, 7V – 0,2 V,
matches the output of your radio to
the input of the amplifier. After instal-
lation is complete, make sure the in-
put of the amplifier is turned down all
the way ( counter-clockwise at 7V ).
TheDLS Reference amplifiers include high pass filter
( HP) and low pass filters (LP). The highpass filter
can also be used as a subsonic filter.
All filters are continously variable and all filters can
be switched on and off.
The slope of all filters are 12 dB / octave.
The filter can be switched off if you want to run the
amplifier in full range mode.
This is the crossover configuration on RA20 & RA40:
RA20:
LP-filter 40 - 125 Hz
HP-filter 20 - 150 Hz
RA40 CH1 & 2: RA40 CH3 & 4:
HP-filter 20 -150 Hz HP-filter 20 - 150 Hz
LP-filter 40 - 125 Hz
The HPF ( high pass filter )
blocks very low frequencies from
reaching the speakers. It is
mostly used at say 60 Hz to
protect small speakers ( like 6
inch and smaller ) from deep
bass. It can also be used as
subsonic filter to take away the
very deepest frequencies from a
bass box. The typical setting is
then around 25 – 40 Hz.
High Pass Filter / Subsonic filter
Low Pass Filter
The LP-filter ( low pass filter) is
mostly used for subwoofers. It will
allow low frequencies only and
blocks higher frequencies.
A typical setting is 50 – 80 Hz.
The filter can be switched IN-OUT
and is available on both RA20 and
RA40.
6
Play a tape or CD, make sure all bass or treble
settings or equalizer are flat, and turn the volume
of the radio up until you just start to hear distortion.
Turn the volume control down just a bit. On the
amplifier increase the input level control ( clockwise
or to the right ) until you just start to hear distortion,
then back the level control just a bit. Now your ra-
dio and amplifier levels are matched.
Grand bass 40 Hz
Grand Bass is used to increase the bass volume
with a center frequency of 40 HZ. You can select
the amplification between 0 dB ( no amplification )
and +18 dB (full amplification).
The phase control on RA20 &
RA40 can be set continuously
from 0 - 180 degrees. This is very
useful when you want to adjust
the bass sound for best front
stage image. Start on 0 and turn
the control slowly clockwise until
you experience that the bass
sound is coming from the front. If
you dont get the result you want,
also try to phase reverse the
subwoofer connections and
make a new adjustment.
Phase control
RA20 & RA40
This function is used to
compensate for the bass box
function and to adjust for your
own taste of bass. Set level
control at 0 dB if you want it
to be inoperative. On RA40
this function is operative only
on channels 3 & 4.
PHASE
0
180
DEGREE
BASS
0
+18
dB
GAIN
7V
0,2V
HP-filter
FREQUENCY
20
150
Hz
LP-filter
FREQUENCY
40
125
Hz