Specifications
G150XG01 
V3  rev  1.0 
6/28 
2.2 Optical Characteristics 
The optical characteristics are measured under stable co
nditions at 25 (Room Temperature): 
Item  Unit  Conditions  Min.  Typ.  Max.  Note 
White Luminance 
[cd/m2] 
100% Dimming 
(center point) 
320  400  -  1 
Uniformity 
% 
9 Points 
75 
80  -  1, 2, 3
Contrast Ratio 
  400 
700  -  4 
Cross talk 
% 
  - 
1.2  1.5  5 
[msec] 
Rising 
- 
5.7 
[msec] 
Falling 
- 
2.3   
Response Time 
[msec] 
Raising + Falling 
- 
8   
6 
[degree] 
[degree] 
Horizontal 
    (Right) 
CR = 10          (Left) 
70 
70 
80 
80 
- 
- 
Viewing Angle 
[degree] 
[degree] 
Vertical 
        (Upper) 
CR = 10        (Lower) 
50 
70 
60 
80 
- 
- 
7 
Red x 
0.577 
0.627
0.677 
Red y 
0.298 
0.348
0.398 
Green x 
0.288 
0.338
0.388 
Green y 
0.539 
0.589
0.639 
Blue x 
0.100 
0.150
0.200 
Blue y 
0.029 
0.079
0.129 
White x 
0.263 
0.313
0.363 
Color / Chromaticity 
Coordinates 
(CIE 1931) 
White y 
0
.279  0.329
0.379 
Color Gamut  % 
- 
60  -   
Gamma Value   
- 
2.2  -  8 
Note 1: Measurement method 
Equipment Pattern Generator, Power Supply, Digital 
Voltmeter, Luminance meter (SR_3 or equivalent) 
Aperture     
Test Point          Center   
Environment      < 1 lux 
LCD Module
SR_3 or 
equivalent 
Measuring distance
Module Driving Equipment
Data Modul AG - www.data-modul.com
7