Specifications
  5  Rev. 11©1999 - 2010 DMC Co., Ltd. 
2. Testing Regulation 
2-1. Testing Regulation 
§ If the regulation is not specified, the test is performed under the supplier’s regulation. 
§ Tests are performed under the room temperature unless specified. The room temperature is referred as 
follows: 
Temperature: 20°C±5°C 
Humidity: 65%±10%RH 
2-2. Environmental Specifications 
§ Chemical Resistance Test 
Condition:  Tested after leaving the chemical on the surface for 12 hours being wiped off by cloth. 
Judgement:  Must be no effect in appearance. 
2-3. Mechanical Characteristics 
§ Activation Force Test 
Condition:  Measured by depressing the point between 
the dots to the conduction by the testing rod 
(Figure 1). 
Judgement:  Must satisfy the specification. 
§ Operating Life Test (Finger) 
Condition:  Testing rod: Refer to Figure 1 
Voltage: DC5V 
Load: 3N 
Cycle: 2 hits/sec 
Judgement:  Must satisfy the following: 
Activation Force:  Must satisfy the specification. 
Linearity:  Must satisfy the specification. 
Terminal Resistance:  Must satisfy the specification. 
Insulation Resistance:  Must satisfy the specification. 
§ Operating Life Test (Pen) 
Condition:  Testing rod: Refer to Figure 2 
Voltage: DC5V 
Load: 2.5N 
Input size:  10 x 10 mm 
Input character:   A to Z/minute 
Judgement:  Must satisfy the following: 
Activation Force:  Must satisfy the specification. 
Linearity:  Must satisfy the specification. 
Terminal Resistance:  Must satisfy the specification. 
Insulation Resistance:  Must satisfy the specification. 
Polyacetal resin 
Tip: R = 0.8 
Figure 2. Testing rod 2 
Silicon Rubber 
(Hardness: 60°) 
Tip: R = 4.0 
Figure 1. Testing rod 1 
Data Modul AG - www.data-modul.com