Specifications
G121SN01  V4  rev.  1.4 
P
age  18/24 
G
121SN01 V4 
6.6 Power ON/OFF Sequence 
VDD power and lamp on/off sequence is as below. Inte
rface signals are also shown in the chart. Signals from 
any system shall be Hi-Z state or low level when VDD is off. 
Power ON/OFF sequence timing 
Value 
Parameter 
Min.  Typ.  Max. 
Units 
T1  0.5  -  10  [ms] 
T2  30  40  50  [ms] 
T3  175  -  -  [ms] 
T4  10  -  -  [ms] 
T5  10  -  -  [ms] 
T6  0  -  -  [ms] 
T7  10  -  -  [ms] 
T8  100  -  -  [ms] 
T9  0  16  50  [ms] 
T10  -  -  10  [ms] 
T11  1000  -  -  [ms] 
The above on/off sequence should be applied to avoid abnormal function in the display. Please make sure to turn 
off the power when you plug the cable into the input connector or pull the cable out of the connector. 