Specifications

  7  Rev. 11©1999 - 2010 DMC Co., Ltd. 
3. Reliability Condition 
3-1. Temperature Condition 
§ Temperature Condition Test 
Following test are performed in the condition with no dew condensation: 
Cold Test:  Tested after leaving the parts in -40°C±3°C for 240 hours and in the room temperature 
for 2 hours. 
Heat Test:  Tested after leaving the parts in 80°C±3°C for 240 hours and in the room temperature for 
2 hours. 
Humidity Test:  Tested after leaving the parts in the temperature 60°C±3°C, humidity 90 to 95% for 240 
hours and in the room temperature for 2 hours. 
Cycle Test:  Tested after 5 cycles of leaving the parts in the temperature -30°C±3°C for 1 hour and in 
the room temperature for 0.5 hours, then leaving the parts in the temperature 70°C±3°C 
for 1 hour and in the room temperature for 0.5 hours. 
Judgement:  Must satisfy the following: 
Activation Force:  Must satisfy the specification. 
Linearity:  Must satisfy the specification. 
Terminal Resistance:  Must satisfy the specification. 
Insulation Resistance:  Must satisfy the specification. 
Appearance:  Must satisfy the specification. 
4. Recommended Connector 
4-1. Recommended Connector 
Part No.  Pins  Pitch 
KCA-K4R  4 pin Double-sided  1.25mm 
Data Modul AG - www.data-modul.com